Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/1573
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Electrical Engineering | - |
dc.creator | Wang, Y | - |
dc.creator | Che, Y | - |
dc.creator | Cheng, KWE | - |
dc.date.accessioned | 2014-12-11T08:26:30Z | - |
dc.date.available | 2014-12-11T08:26:30Z | - |
dc.identifier.isbn | 978-988-17471-3-6 | - |
dc.identifier.uri | http://hdl.handle.net/10397/1573 | - |
dc.language.iso | en | en_US |
dc.publisher | Power Electronics Research Centre, The Hong Kong Polytechnic University | en_US |
dc.rights | Copyright © The Hong Kong Polytechnic University 2009. | en_US |
dc.subject | Three-Phase PWM Voltage Source Rectifier | en_US |
dc.subject | Voltage-oriented | en_US |
dc.subject | Dual-channel closed-loop control | en_US |
dc.subject | Voltage-outer-loop | en_US |
dc.subject | Current q-axis component | en_US |
dc.title | Research on control strategy for Three-Phase PWM Voltage Source Rectifier | en_US |
dc.type | Conference Paper | en_US |
dc.description.otherinformation | Author name used in this publication: K. W. E. Cheng | en_US |
dcterms.abstract | This paper first introduces the topology of Three-Phase PWM Voltage Source Rectifier (VSR). Then the mathematical models in three-phase static and two-phase rotary coordinate system are built. Based on that theory and the voltage-oriented vector control's idea, the paper introduces a dual-channel closed-loop control strategy with current-inner-loop and voltage-outer-loop. Active power channel is aim to make DC side voltage remain steady, and reactive power channel can regulate power factor by set current q-axis component reference. In order to prove that voltage-outer-loop is necessary, the paper builds a comparative model without a voltage loop. According to change current q-axis component reference value, illuminate reactive power channel's effect. In MATLAB/SIMULINK, the paper sets up simulation models for above cases. The simulation results show that the voltage-outer-loop is essential, and prove that current q-axis component can regulate power factor. The Three-Phase PWM Voltage Source Rectifier dual-channel double-closed-loop control strategy is effect. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | PESA 2009 : International Conference on Power Electronic Systems and Applications : 20th-22nd May 2009, p. [1-5] | - |
dcterms.issued | 2009 | - |
dc.identifier.scopus | 2-s2.0-70350455224 | - |
dc.relation.ispartofbook | PESA 2009 : International Conference on Power Electronic Systems and Applications : 20th-22nd May 2009 | - |
dc.description.oa | Version of Record | en_US |
dc.identifier.FolderNumber | OA_IR/PIRA | en_US |
dc.description.pubStatus | Published | en_US |
dc.description.oaCategory | Publisher permission | en_US |
Appears in Collections: | Conference Paper |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
PESA_2009_K210509081.pdf | 1.01 MB | Adobe PDF | View/Open |
Page views
133
Last Week
1
1
Last month
Citations as of Apr 13, 2025
Downloads
321
Citations as of Apr 13, 2025
SCOPUSTM
Citations
9
Last Week
0
0
Last month
0
0
Citations as of Jun 21, 2024

Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.