Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/121279
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorMainland Development Office-
dc.creatorHuang, E-
dc.creatorChang, Y-
dc.creatorLiu, Y-
dc.creatorDai, K-
dc.creatorChen, P-
dc.date.accessioned2026-09-21T06:07:08Z-
dc.date.available2026-09-21T06:07:08Z-
dc.identifier.urihttp://hdl.handle.net/10397/121279-
dc.language.isoenen_US
dc.publisherMDPI AGen_US
dc.rightsCopyright: © 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).en_US
dc.rightsThe following publication Huang, E., Chang, Y., Liu, Y., Dai, K., & Chen, P. (2026). Vortex Structure and Aerodynamic Loads of a Pentagonal Heliostat for Concentrating Solar Power: A CFD Study. Fluids, 11(2), 54 is available at https://doi.org/10.3390/fluids11020054.en_US
dc.subjectAerodynamic Force Coefficientsen_US
dc.subjectComputational Fluid Dynamics (CFD)en_US
dc.subjectFlow fielden_US
dc.subjectPentagonal heliostaten_US
dc.titleVortex structure and aerodynamic loads of a pentagonal heliostat for concentrating solar power : a CFD studyen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume11-
dc.identifier.issue2-
dc.identifier.doi10.3390/fluids11020054-
dcterms.abstractHeliostats constitute essential elements within concentrating solar power (CSP), where their structure, load profiles, and operational environment render wind loads a critical factor in their design considerations, as these loads directly impact the cost of energy generation. The aerodynamics significantly influence wind-induced effects, resulting in considerable variability in wind loads among different heliostat geometries. This study utilizes the Computational Fluid Dynamics (CFD) methodology to systematically examine the aerodynamic behavior of an isolated pentagonal heliostat. Employing the Unsteady Reynolds-Averaged Navier–Stokes (URANS) equations with an atmospheric boundary layer inlet condition, the investigation focuses on the flow field and wind load characteristics at four representative pitch angles: 0° (stow position), 30°, 60°, and 90°. Findings indicate that the pitch angle exerts a decisive impact on flow separation patterns. Specifically, as the elevation angle decreases, the flow regime shifts from being predominantly influenced by the mirror surface to being governed by the support structure, mediated through an interactive coupling between these components. At the 60° operational pitch angle, the pentagonal heliostat’s distinctive corner geometry induces an asymmetric vortex configuration—characterized by a smaller vortex at the top and a larger one at the bottom—thereby disrupting the conventional vortex distribution observed in symmetric heliostat designs. A further analysis of wind load characteristics indicates that, compared to a quadrilateral heliostat, the pentagonal mirror exhibits a significantly lower Elevation Moment Coefficient, despite a slight increase in the normal force coefficient. This reduction is attributed to a balancing mechanism: the “vortex structure asymmetry” creates an upper-large–lower-small distribution of absolute negative pressure on the support surface, while the “stagnation point position” shift with elevation angle produces an upper-small–lower-large distribution of absolute positive pressure on the reflector. The interaction between these opposing trends minimizes the net pressure differential across the mirror height, thereby contributing to superior overall aerodynamic performance. The reduction in the elevation moment coefficient contributes to enhanced structural wind resistance, thereby improving the overall energy efficiency and economic viability of concentrating solar power.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationFluids, Feb. 2026, v. 11, no. 2, 54-
dcterms.isPartOfFluids-
dcterms.issued2026-02-
dc.identifier.scopus2-s2.0-105031428781-
dc.identifier.eissn2311-5521-
dc.identifier.artn54-
dc.description.validate202609 bcch-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_Scopus/WOSen_US
dc.description.fundingSourceOthersen_US
dc.description.fundingTextThis research was funded by the National Natural Science Foundation of China (No. 52308514); Natural Science Foundation of Sichuan (No. 2024NSFSC0931).en_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryCCen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
fluids-11-00054-v3.pdf12.5 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.