Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/119361
DC FieldValueLanguage
dc.contributorDepartment of Civil and Environmental Engineeringen_US
dc.creatorWang, Xen_US
dc.creatorCao, Jen_US
dc.creatorChung, KFen_US
dc.creatorDing, Yen_US
dc.creatorZhou, Xen_US
dc.date.accessioned2026-06-17T00:47:38Z-
dc.date.available2026-06-17T00:47:38Z-
dc.identifier.issn0141-0296en_US
dc.identifier.urihttp://hdl.handle.net/10397/119361-
dc.language.isoenen_US
dc.publisherElsevier Ltden_US
dc.subjectConcrete-filled steel tubesen_US
dc.subjectEnergy dissipationen_US
dc.subjectExperimental investigationsen_US
dc.subjectSeismic behaviouren_US
dc.subjectSelf-centeringen_US
dc.titleExperimental investigation into seismic performance of self-centering rocking piers of concrete-filled steel tubes with bottom encasementsen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume359en_US
dc.identifier.doi10.1016/j.engstruct.2026.122649en_US
dcterms.abstractThis paper presents an advanced structural system of self-centering (SC) rocking piers made of concrete filled steel tubes (CFST) with bottom encasements, and a number of unbonded post-tensioned (PT) strands and energy dissipation (ED) steel bars are also provided to enhance their performance under seismic actions. A total of seven CFST pier specimens were tested under quasi-static lateral loads, and their seismic responses were described thoroughly in this paper. Key parameters included various geometrical dimensions in the CFST piers, the bottom encasements, the PT strands and the ED steel bars together with their axial load ratios, and typical failure modes and deformation characteristics of these piers were identified. All the test specimens failed due to extensive yielding of ED bars and damage to the concrete at the bottom encasement. It is shown that with an increase in the ED bar ratio, the deformation characteristics of the CFST piers, including bending stiffness and resistance, and energy dissipation capacity are significantly increased while the self-centering capacity is decreased correspondingly. Moreover, increasing the diameter of the bottom encasements is able to enhance significantly the bending stiffnesses and resistances of the piers, but this also causes a minor reduction to both the self-centering and the energy dissipation capacities of the SC-CFST piers. With an increase in the applied compression forces to the SC-CFST piers and also the forces in the PT strands, all their deformation characteristics together with their self-centering capacities are increased. After calibration against measured data, a simplified theoretical model is proposed which is shown to be able to estimate the lateral load-drift skeleton curves of these self-centering piers with a high level of accuracy.en_US
dcterms.accessRightsembargoed accessen_US
dcterms.bibliographicCitationEngineering structures, 15 July 2026, v. 359, 122649en_US
dcterms.isPartOfEngineering structuresen_US
dcterms.issued2026-07-15-
dc.identifier.scopus2-s2.0-105034745203-
dc.identifier.eissn1873-7323en_US
dc.identifier.artn122649en_US
dc.description.validate202606 bchyen_US
dc.description.oaNot applicableen_US
dc.identifier.SubFormIDG001858/2026-05-
dc.description.fundingSourceOthersen_US
dc.description.fundingTextThe financial support offered by the National Natural Science Foundation of China (No. 52378129 ) is acknowledged. The financial support from the Chinese National Engineering Research Centre for Steel Construction (Hong Kong Branch) (Project No. K-BBY3 ) is also acknowledged.en_US
dc.description.pubStatusPublisheden_US
dc.date.embargo2028-07-15en_US
dc.description.oaCategoryGreen (AAM)en_US
Appears in Collections:Journal/Magazine Article
Open Access Information
Status embargoed access
Embargo End Date 2028-07-15
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.