Title: Compressive behavior of concrete-filled filament-wound FRP tubes with local tube damage
Authors: Lin, G
Xiang, Y 
Issue Date: Apr-2023
Source: Journal of composites for construction, Apr. 2023, v. 379, 04023005, p. 04023005-1 - 04023005-13
Abstract: Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) are an emerging and attractive form of column for new construc-tions. Such a column consists of outer filament-wound FRP tubes that are filled with plain or steel-reinforced concrete. The fibers in the fil-ament-wound FRP tube are predominantly in the hoop direction to confine the inner concrete, which leads to significantly enhanced strengthand ductility in the confined concrete. Extensive studies have been conducted on the behavior of CFFTs that were subjected to various loadingconditions, which confirmed the excellent performance of such members. As CFFTs become increasingly used in practice, there is a concernabout the performance of CFFTs when the FRP tube is subjected to local damage that is caused by accidents, vandalism, or designed holes orcuts to accommodate connections with other structural components. Some studies have been carried out on the performance of CFFTs asflexural members with a locally damaged filament-wound FRP tube; however, the research on such CFFTs as columns remains limited.This paper presented the results of a comprehensive experimental program on the axial compressive behavior of CFFTs with a filament-wound FRP tube that was subjected to local tube damage. Two types of damage (i.e., holes and cuts) with different parameters were inves-tigated. The test results showed that the compressive strength [i.e., peak stress ( f ′cc )] and the corresponding axial strain (ɛcc ) of the damagedCFFTs were significantly reduced due to the local tube damage (e.g., f ′cc reduced from 12.2% to 64.8% and the corresponding ɛcc reducedfrom 35.2% to 77.2%). Finally, an existing model for FRP-confined concrete that considered the local FRP damage was evaluated whichsuggested the need for the recalibration of the model or the development of a new model for CFFTs with a locally damaged filament-wound FRP tube.
Keywords: Compressive behavior
Confinement
Fiber-reinforced polymer
Filament-wound FRP tubes
Local damage
Publisher: American Society of Civil Engineers
Journal: Journal of composites for construction 
ISBN:  
ISSN: 1090-0268
EISSN: 1943-5614
DOI: 10.1061/JCCOF2.CCENG-4030
Rights: © 2023 American Society of Civil Engineers.
This material may be downloaded for personal use only. Any other use requires prior permission of the American Society of Civil Engineers. This material may be found at https://ascelibrary.org/doi/10.1061/JCCOF2.CCENG-4030.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Lin_Compressive_Behavior_Concrete-Filled.pdfPre-Published version7.47 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.