| Title: | Assessing the validity and reliability of the PNOE̅ for measuring cardiometabolic outcomes during walking exercise | Authors: | Kwok, MMY Ng, SSM Myers, J So, BCL |
Issue Date: | Jun-2025 | Source: | Journal of functional morphology and kinesiology, June 2025, v. 10, no. 2, 159 | Abstract: | Background: The accuracy of measurement of cardiometabolic outcomes in terms of gaseous exchange and energy expenditure of individuals is crucial. The objective of this study was to compare the validity and reliability of the PNOE̅ in measuring cardiometabolic outcomes from the respiratory gaseous exchange of healthy individuals during treadmill walking exercise. Methods: A total of 21 healthy subjects (15 male and 6 female) aged 22.76 ± 3.85 years took part in this study. Oxygen uptake (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (RER), metabolic equivalents (METs), tidal volume (VT), and energy expenditure (EE) were measured using the PNOE̅ and COSMED K5 portable systems during a twenty-eight-minute, four-stage incremental protocol, where speed increased from 1.7 mph to 4.2 mph with a 2% incline on a treadmill. Test–retest reliability was tested on separate days with trail repetition. Validity was evaluated by Bland–Altman plots, intraclass correlation coefficients (ICCs) and mean percentage difference. Results: ICCs showed that VCO2 was in the good range (0.75–0.90). The ICC of the RER from stages 1 to 3 of the incremental protocol and the VT from stages 2 to 4 of the incremental protocol showed good to excellent reliability. No clear trend was seen for VO2, VCO2, and EE datapoints with variations in speed. Pearson’s correlation coefficients were moderately high (r = 0.60–0.79) between VO2, VCO2, RER, METs, VT, and EE measured by the PNOE̅ and K5 systems. All subjects, except for a few cases in VT, were within the upper and lower 95% confidence intervals of the acceptable range of the Bland–Altman plots. Conclusions: The PNOE̅ system is a valid and reliable measure of cardiometabolic outcomes and is comparable to the COSMED K5 system. |
Keywords: | Accuracy assessment Aerobic capacity Kinesiology Portable metabolic system |
Publisher: | MDPI AG | Journal: | Journal of functional morphology and kinesiology | EISSN: | 2411-5142 | DOI: | 10.3390/jfmk10020159 | Rights: | Copyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). The following publication Kwok, M. M. Y., Ng, S. S. M., Myers, J., & So, B. C. L. (2025). Assessing the Validity and Reliability of the PNOE̅ for Measuring Cardiometabolic Outcomes During Walking Exercise. Journal of Functional Morphology and Kinesiology, 10(2), 159 is available at https://doi.org/10.3390/jfmk10020159. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| jfmk-10-00159-v2.pdf | 2.27 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.