Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/114638
PIRA download icon_1.1View/Download Full Text
Title: Algorithmic scatter correction in dual-energy digital mammography for calcification imaging
Authors: Chen, X
Nishikawa, RM
Chan, ST 
Lau, BA
Zhang, L 
Mou, X
Issue Date: 2012
Source: Proceedings of SPIE : the International Society for Optical Engineering, 2012, v. 8313, 83130E
Abstract: X-ray scatter leads to erroneous calculations of dual-energy digital mammography (DEDM). The purpose of this work is to design an algorithmic method for scatter correction in DEDM without extra exposures or lead sheet. The method was developed based on the knowledge that scatter radiation in mammograms varies slowly spatially and most pixels in mammograms are non-calcification pixels, and implemented on a commercial full-field digital mammography system with a phantom of breast tissue equivalent material. The pinhole-array interpolation scatter correction method was also implemented on the system. We compared the background dual-energy (DE) calcification signals in the DE calcification images. Results show that the background signal in the DE calcification image can be reduced. The rms of background DE calcification image signal of 1105μm with scatter-uncorrected data was reduced to 187μm and 253μm after scatter correction, using our algorithmic method and pinhole-array interpolation method, respectively. The range of background DE calcification signals using scatter-uncorrected data was reduced by ~80% with scatter-corrected data using algorithmic method. The proposed algorithmic scatter correction method is effective; it has similar or even better performance than pinhole-array interpolation method in scatter correction for DEDM.
Keywords: Calcification
Digital mammography
Dual-energy
Scatter correction
Publisher: SPIE - International Society for Optical Engineering
Journal: Proceedings of SPIE : the International Society for Optical Engineering 
ISSN: 0277-786X
EISSN: 1996-756X
DOI: 10.1117/12.911775
Description: SPIE Medical Imaging, 4-9 February 2012, San Diego, California, United States
Rights: Copyright 2012 Society of Photo‑Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this publication for a fee or for commercial purposes, and modification of the contents of the publication are prohibited.
The following publication Xi Chen, Robert M. Nishikawa, Suk-Tak Chan, Beverly A. Lau, Lei Zhang, and Xuanqin Mou "Algorithmic scatter correction in dual-energy digital mammography for calcification imaging", Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 83130E (2 March 2012) is available at https://doi.org/10.1117/12.911775.
Appears in Collections:Conference Paper

Files in This Item:
File Description SizeFormat 
83130E.pdf412.37 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.