Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/114172
PIRA download icon_1.1View/Download Full Text
Title: Performance evaluation of high-volume evacuation for removing droplets during dental treatment
Authors: Xing, C
Ai, Z
Mak, CM 
Wong, HM
Issue Date: Dec-2024
Source: Building simulation, Dec. 2024, v. 17, no. 12, p. 2263-2280
Abstract: The high-volume evacuation (HVE) is commonly employed as a primary source control measure for removing splatter emitted from mouth during dental treatments, but there is still a lack of comprehensive understanding of its efficiency. Based on our previous experiments on the emission characteristics during dental treatments, this study employed computational fluid dynamics (CFD) simulations to investigate the impact of emission parameters (droplet size, emission velocity, emission angle), HVE usage methods (distance between HVE and the droplet release source), and HVE suction flow rates on its removal efficiency. The effect of HVE on fallow time (FT) was also examined. Cumulative removal efficiency that accurately reflected the HVE effect was proposed as an evaluation index. It was found that emission velocity and distance between HVE and the source were key factors determining cumulative removal efficiency. When the distance was 4 cm, the cumulative removal efficiencies for low-velocity (0.8 m/s), medium-velocity (3.4 m/s), and high-velocity droplets (6.0 m/s) were approximately 97.9%, 73.6%, and 58.0%, respectively. For high-velocity droplets at 6.0 m/s, decreasing the distance from 4 cm to 2 cm and 1 cm increased the cumulative removal efficiency from 58.0% to 76.7% and 100%. This study was expected to enhance the understanding of HVE performance and provide information on its usage method. It also indicated the need for developing advanced control measures that could have high efficiency in removing both low-velocity and high-velocity droplets.
Keywords: Computational fluid dynamics (CFD)
Fallow time (FT)
High-speed air turbine handpiece (HATH)
High-volume evacuation (HVE)
Powder jet handpieces (PJH)
Ultrasonic scaling instruments (USI)
Publisher: Tsinghua University Press
Journal: Building simulation 
ISSN: 1996-3599
EISSN: 1996-8744
DOI: 10.1007/s12273-024-1187-5
Rights: © Tsinghua University Press 2024
This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use (https://www.springernature.com/gp/open-research/policies/accepted-manuscript-terms), but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: http://dx.doi.org/10.1007/s12273-024-1187-5.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Xing_Performance_Evaluation_Hhigh-volume.pdfPre-Published version3.25 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.