Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/114171
DC FieldValueLanguage
dc.contributorDepartment of Building Environment and Energy Engineering-
dc.creatorLi, Wen_US
dc.creatorMak, CMen_US
dc.creatorFu, Yen_US
dc.creatorCai, Cen_US
dc.creatorTse, KTen_US
dc.creatorNiu, Jen_US
dc.date.accessioned2025-07-15T08:43:43Z-
dc.date.available2025-07-15T08:43:43Z-
dc.identifier.issn0360-1323en_US
dc.identifier.urihttp://hdl.handle.net/10397/114171-
dc.language.isoenen_US
dc.publisherElsevier BVen_US
dc.subjectTandem non-identical-height buildingen_US
dc.subjectThermal comforten_US
dc.subjectWind assessmenten_US
dc.subjectWind comforten_US
dc.subjectWind tunnelen_US
dc.titleThe impact of twisted wind on pedestrian comfort around two non-identical-height buildings in tandem arrangement: a wind tunnel studyen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume262en_US
dc.identifier.doi10.1016/j.buildenv.2024.111847en_US
dcterms.abstractDue to the impact of urbanization, an increasing number of buildings are being constructed near hilly terrains because of the limited availability of land resources. The influence of twisted wind profile (TWP) on pedestrian-level wind comfort surrounding two tandem non-identical-height buildings, with a height ratio H1/H2 ranging from 3:1 to 1:0.33, was investigated by wind tunnel experiment with two twist angles (13 ° and 25 °), and compared with the conventional wind profile (CWP). The assessment of thermal comfort was based on Physiologically Equivalent Temperature (PET) using wind velocity measured from the wind tunnel and observation results. Both the mean and gust wind velocities were investigated and compared with wind assessment criteria. The results reveal a significant disparity in the mean and gust wind fields for various H1/H2 under both CWP and TWPs, with the influence of twist being more pronounced for step-up building configuration (H1<H2). The influence of TWPs on the low wind velocity region demonstrated contrasting patterns for buildings with step-up and step-down configurations. The pedestrian level wind environment varies significantly with H1/H2 under CWP and TWPs in the passage between the two tandem buildings, categorized as “Sitting long” for identical-height buildings and modified to “Strolling” and “Walking fast” for step-up building configuration. The twisted wind shifts the “Sitting short” area toward the direction of the approaching twisted wind flow and amplifies the “Strolling” area on the other side. The twisted wind can diminish the thermal comfort surrounding the two tandem structures during summer while enhancing the thermal environment in winter.-
dcterms.accessRightsembargoed accessen_US
dcterms.bibliographicCitationBuilding and environment, 15 Aug. 2024, v. 262, 111847en_US
dcterms.isPartOfBuilding and environmenten_US
dcterms.issued2024-08-15-
dc.identifier.scopus2-s2.0-85199174103-
dc.identifier.eissn1873-684Xen_US
dc.identifier.artn111847en_US
dc.description.validate202507 bcch-
dc.identifier.FolderNumbera3879b-
dc.identifier.SubFormID51518-
dc.description.fundingSourceRGCen_US
dc.description.pubStatusPublisheden_US
dc.date.embargo2026-08-15en_US
dc.description.oaCategoryGreen (AAM)en_US
Appears in Collections:Journal/Magazine Article
Open Access Information
Status embargoed access
Embargo End Date 2026-08-15
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

SCOPUSTM   
Citations

5
Citations as of Dec 19, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.