Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/114059
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorSchool of Optometry-
dc.contributorResearch Centre for SHARP Vision-
dc.creatorLam, AKC-
dc.creatorLee, SNS-
dc.creatorMui, MWS-
dc.creatorNg, VHY-
dc.date.accessioned2025-07-10T06:21:49Z-
dc.date.available2025-07-10T06:21:49Z-
dc.identifier.urihttp://hdl.handle.net/10397/114059-
dc.language.isoenen_US
dc.publisherFrontiers Media SAen_US
dc.rights© 2025 Lam, Lee, Mui and Ng. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.en_US
dc.rightsThe following publication Lam, A. K. C., Lee, S. N. S., Mui, M. W. S., & Ng, V. H. Y. (2025). Short-term digital ocular massage may weaken corneal biomechanics [Original Research]. Frontiers in Bioengineering and Biotechnology, Volume 13 - 2025 is available at https://doi.org/10.3389/fbioe.2025.1582973.en_US
dc.subjectCorneal biomechanicsen_US
dc.subjectStress strain indexen_US
dc.subjectMyopiaen_US
dc.subjectMassageen_US
dc.subjectIntraocular pressureen_US
dc.titleShort-term digital ocular massage may weaken corneal biomechanicsen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.doi10.3389/fbioe.2025.1582973-
dcterms.abstractPurpose: Digital ocular massage has been demonstrated to reduce intraocular pressure (IOP). However, its influence on corneal biomechanics remains unclear. In this study, a device employing Corneal Visualization Scheimpflug Technology (Corvis ST) was used to monitor changes in IOP and corneal biomechanics following short-term digital ocular massage in low and high myopes.-
dcterms.abstractMethods: In total, 29 low myopes and 29 high myopes participated in this study. The right eyes (treatment eyes) underwent digital ocular massage for 5 min, whereas the left eyes (control eyes) remained closed during the procedure. Biomechanically-corrected IOP (bIOP) was measured in both eyes by using Corvis ST at three time points: before the ocular massage, immediately after the ocular massage, and 15 min post-massage. Dynamic corneal response (DCR) parameters were also monitored, namely, peak distance (PeakDist), highest concavity time (HCT), deformation amplitude (DA), deflection amplitude (DefleA), stress-strain index (SSI), time taken to reach the second applanation (A2T), and velocity required to reach the second applanation (A2V).-
dcterms.abstractResults: At baseline, the participants exhibited comparable bIOP in both eyes. A significant reduction in bIOP was observed in the treatment eyes immediately after ocular massage (low myopes: 16.15 ± 2.79 vs. 14.82 ± 3.20 mmHg, p < 0.05; high myopes: 16.81 ± 1.51 vs. 15.39 ± 1.70 mmHg, p < 0.05). Corneal biomechanics at baseline were comparable between the treatment and control eyes. High myopes exhibited more deformable corneas, characterized by a shorter HCT (treatment eyes: 17.30 ± 0.41 vs. 17.72 ± 0.30 msec, p < 0.001; control eyes: 17.33 ± 0.32 vs. 17.55 ± 0.44 msec, p = 0.023), and lower SSI (treatment eyes: 0.739 ± 0.100 vs. 0.848 ± 0.114, p < 0.001; control eyes: 0.741 ± 0.103 vs. 0.858 ± 0.112, p < 0.001) than low myopes at baseline. Immediately after ocular massage, the treatment eyes in both groups exhibited shorter A2T, higher A2V, larger PeakDist, and higher DA and DefleA. Corneal biomechanics in the control eyes remained stable throughout. All DCR parameters returned to baseline levels 15 min after the ocular massage.-
dcterms.abstractConclusion: Short-term digital ocular massage results in a temporary reduction in bIOP. The observed changes, including shorter A2T, higher A2V, larger PeakDist, and greater DA and DefleA indicated a greater corneal deformability after ocular massage. These findings support the potential association between eye rubbing and the etiology or progression of keratoconus.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationFrontiers in bioengineering and biotechnology, 2025, v. 13, https://doi.org/10.3389/fbioe.2025.1582973-
dcterms.isPartOfFrontiers in bioengineering and biotechnology-
dcterms.issued2025-
dc.identifier.eissn2296-4185-
dc.description.validate202507 bcch-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumbera3828en_US
dc.identifier.SubFormID51270en_US
dc.description.fundingSourceRGCen_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryCCen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
fbioe-1-1582973.pdf865.36 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Google ScholarTM

Check

Altmetric