Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/113232
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Civil and Environmental Engineering-
dc.creatorPan, B-
dc.creatorDuan, HF-
dc.creatorKeramat, A-
dc.creatorMeniconi, S-
dc.creatorBrunone, B-
dc.date.accessioned2025-05-29T07:59:31Z-
dc.date.available2025-05-29T07:59:31Z-
dc.identifier.issn0043-1397-
dc.identifier.urihttp://hdl.handle.net/10397/113232-
dc.language.isoenen_US
dc.publisherWiley-Blackwell Publishing, Inc.en_US
dc.rights© 2022. American Geophysical Union. All Rights Reserved.en_US
dc.titleEfficient pipe burst detection in tree-shape water distribution networks using forward-backward transient analysisen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume58-
dc.identifier.issue11-
dc.identifier.doi10.1029/2022WR033465-
dcterms.abstractTransient-based leak/burst detection has received more and more attentions in the operation and management of water distribution networks. However, with the increase in pipe network complexity, it is hard to detect and locate the potential pipe defects and water losses efficiently. Recently, we proposed an efficient leak/burst localization strategy in single pipelines based on the forward and backward transient analysis, and in this work, this effective approach is customized for the more realistic branched (tree-shaped) pipe networks. Unlike traditional transient-based methods which rely on tedious optimization procedures, the proposed method uses a mismatch property between forward and backward analyses of transient signals for the pipe burst detection during the water supply process. Compared with other developed methods, this method can directly calculate the defect location, so it is expected to have high efficiency and wide applicability. To fulfill this goal, a framework for burst detection in a tree-shaped pipe network is developed in this paper. Using the mass conservation and energy relations at the branched junctions, the forward and backward transient analysis is extended from one pipe to another until the burst is found and then located in the network. Both experimental and numerical tests show the effectiveness of the proposed method, and further analysis has shown that the method is also valid for leak detection in both transient and steady conditions, confirming the robustness and practicality of this proposed method. At last, this paper discusses the influence of transient sources and the potential combination of the method with other methods.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationWater resources research, Nov. 2022, v. 58, no. 11, e2022WR033465-
dcterms.isPartOfWater resources research-
dcterms.issued2022-11-
dc.identifier.scopus2-s2.0-85142883238-
dc.identifier.eissn1944-7973-
dc.identifier.artne2022WR033465-
dc.description.validate202505 bcch-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_Othersen_US
dc.description.fundingSourceRGCen_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryVoR alloweden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Pan_Efficient_Pipe_Burst.pdf4.74 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

SCOPUSTM   
Citations

15
Citations as of Dec 19, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.