Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/112523
| DC Field | Value | Language |
|---|---|---|
| dc.contributor | Department of Biomedical Engineering | - |
| dc.contributor | Research Institute for Smart Ageing | - |
| dc.creator | Huang, ZH | - |
| dc.creator | Deng, MQ | - |
| dc.creator | Lin, Y | - |
| dc.creator | Ye, CH | - |
| dc.creator | Zheng, MH | - |
| dc.creator | Zheng, YP | - |
| dc.date.accessioned | 2025-04-16T04:33:45Z | - |
| dc.date.available | 2025-04-16T04:33:45Z | - |
| dc.identifier.uri | http://hdl.handle.net/10397/112523 | - |
| dc.language.iso | en | en_US |
| dc.publisher | BioMed Central Ltd. | en_US |
| dc.rights | © The Author(s) 2024. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. | en_US |
| dc.rights | The following publication Huang, ZH., Deng, MQ., Lin, Y. et al. Body posture can modulate liver stiffness measured by transient elastography: a prospective observational study. BMC Gastroenterol 24, 386 (2024) is available at https://doi.org/10.1186/s12876-024-03473-8. | en_US |
| dc.subject | Body position | en_US |
| dc.subject | Liver fibrosis | en_US |
| dc.subject | Liver stiffness measurement | en_US |
| dc.subject | Measuring posture | en_US |
| dc.subject | Patient positioning | en_US |
| dc.subject | Ultrasound elastography | en_US |
| dc.title | Body posture can modulate liver stiffness measured by transient elastography : a prospective observational study | en_US |
| dc.type | Journal/Magazine Article | en_US |
| dc.identifier.volume | 24 | - |
| dc.identifier.issue | 1 | - |
| dc.identifier.doi | 10.1186/s12876-024-03473-8 | - |
| dcterms.abstract | Background: Non-invasive measurement of liver stiffness (LS), traditionally performed in the supine position, has been established to assess liver fibrosis. However, fibrosis degree is not the sole determinant of LS, necessitating the identification of relevant confounders. One often-overlooked factor is body posture, and it remains unclear whether normal daily postures interfere with LS irrespective of fibrosis. A prospective two-group comparison study was conducted to investigate the relationship between posture and LS. | - |
| dcterms.abstract | Methods: Sixty-two adults participated, divided into two groups: patients with chronic liver disease and healthy controls. Both groups were assessed using transient elastography (TE) under the supine, seated, and standing postures. Randomization was applied to the order of the two upright postures. A two-way mixed ANOVA was conducted to assess the posture-dependence of LS and its variations between two groups. | - |
| dcterms.abstract | Results: Results showed that posture differentially affected LS depending on the presence of liver fibrosis. In 31 healthy individuals (baseline LS range: 3.5–6.8 kPa), a transition from the supine (5.0 ± 1.0 kPa) to seated (5.7 ± 1.4 kPa; p = 0.036) or standing (6.2 ± 1.7 kPa; p = 0.002) positions increased LS, indicating liver stiffening. Conversely, in 31 patients with varying fibrosis stages (baseline LS range: 8.8–38.2 kPa), posture decreased LS from the supine (15.9 ± 7.3 kPa) to seated (13.8 ± 6.2 kPa; p < 0.001) or standing (13.9 ± 6.2 kPa; p = 0.001) positions. No significant difference in LS was observed between the seated and standing positions in both groups (control group: 5.7 vs. 6.2 kPa, p = 0.305; patient group: 13.8 vs. 13.9 kPa, p = 1). Additionally, different postures did not elicit significant changes in the success rate (supine, 98.6 ± 4%; seated, 97.6 ± 6%; standing, 99.1 ± 3%; p = 0.258) and IQR/median value (supine, 25 ± 8%; seated, 29 ± 15%; standing, 29 ± 12%; p = 0.117), implying no impact on both measurement feasibility and reliability. | - |
| dcterms.abstract | Conclusions: We demonstrated, for the first time, the feasibility of utilizing upright postures as an alternative measurement protocol for TE. We further unravel a previously unrecognized role of transitioning between different postures to assist the diagnosis of cirrhosis. The findings suggested that daily physiological activity of postural changes suffices to alter LS. Therefore, body positioning should be standardized and carefully considered when interpreting LS. | - |
| dcterms.accessRights | open access | en_US |
| dcterms.bibliographicCitation | BMC gastroenterology, Dec. 2024, v. 24, no. 1, 386 | - |
| dcterms.isPartOf | BMC gastroenterology | - |
| dcterms.issued | 2024-12 | - |
| dc.identifier.scopus | 2-s2.0-85208290682 | - |
| dc.identifier.pmid | 39482593 | - |
| dc.identifier.eissn | 1471-230X | - |
| dc.identifier.artn | 386 | - |
| dc.description.validate | 202504 bcch | - |
| dc.description.oa | Version of Record | en_US |
| dc.identifier.FolderNumber | OA_Scopus/WOS | en_US |
| dc.description.fundingSource | Others | en_US |
| dc.description.fundingText | Tai Hung Fai Charitable Foundation for Henry G. Leong Professor in Biomedical Engineering | en_US |
| dc.description.pubStatus | Published | en_US |
| dc.description.oaCategory | CC | en_US |
| Appears in Collections: | Journal/Magazine Article | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| s12876-024-03473-8.pdf | 1.98 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
3
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
3
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



