Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/111780
PIRA download icon_1.1View/Download Full Text
Title: Ocular surface parameters repeatability and agreement : a comparison between Keratograph 5M and IDRA
Authors: Yin, Chan, K
Liao, X 
Guo, B
Tse, JSH 
Li, PH
Cheong, AMY 
Ngo, W
Lam, TC 
Issue Date: Dec-2024
Source: Contact lens and anterior eye, Dec. 2024, v. 47, no. 6, 102281
Abstract: Purpose: To evaluate the repeatability and agreement in dry eye measurements using Oculus Keratograph 5M (K5M) and SBM Sistemi IDRA (IDRA).
Methods: A total of 108 participants were enrolled and 108 eyes were evaluated. Tear meniscus height (TMH) and first and average non-invasive break-up time (NIBUT) were measured using the K5M and IDRA (order randomly assigned). TMH was measured using the built-in caliper tool while NIBUT was computed by the automatic algorithm of the instruments.
Results: The Bland Altman plots analysis showed a good agreement between the two instruments for TMH (95 % Limits of Agreement (LoA), −0.17 to 0.16), but not the first NIBUT (95 % LoA, −8.13 to 14.79) and average NIBUT (95 % LoA, −7.89 to 10.32). The values of the first and average NIBUT measured using IDRA were significantly shorter than in K5M (difference = median (IQR) −2.75 (−6.48- −0.28)s, p < 0.001 and difference = median (IQR) −1.65 (−3.97–1.89)s, p = 0.008 respectively). The TMH (p = 0.037) and NIBUT average (p = 0.033) measured by K5M, as well as the TMH (p = 0.040) measured by IDRA, exhibited unstable measurements across the three measurement times. The remaining parameters exhibited stability with three repeated measurements.
Conclusion: The NIBUT measurements are not interchangeable between IDRA and K5M, while the TMH was little difference between the two instruments. It is important to exercise caution when using different ocular surface analyzers to minimize errors in comparing multiple measurements.
Keywords: Dry eye
IDRA
Keratograph 5M
NIBUT
Repeatability
Tear film stability
Publisher: Elsevier BV
Journal: Contact lens and anterior eye 
ISSN: 1367-0484
EISSN: 1476-5411
DOI: 10.1016/j.clae.2024.102281
Rights: © 2024 The Author(s). Published by Elsevier Ltd on behalf of British Contact Lens Association. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
The following publication Yin Chan, K., Liao, X., Guo, B., Tse, J. S. H., Li, P. H., Cheong, A. M. Y., Ngo, W., & Lam, T. C. (2024). Ocular surface parameters repeatability and agreement —A comparison between Keratograph 5M and IDRA. Contact Lens and Anterior Eye, 47(6), 102281 is available at https://doi.org/10.1016/j.clae.2024.102281.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
1-s2.0-S1367048424001735-main.pdf520.25 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

6
Citations as of Apr 14, 2025

Downloads

1
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

5
Citations as of Dec 19, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.