Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/111682
Title: | Analytical analysis of the groundwater drawdown difference induced by foundation pit dewatering with a suspended waterproof curtain | Authors: | Yang, K Xu, C Chi, M Wang, P |
Issue Date: | Oct-2022 | Source: | Applied sciences, Oct. 2022, v. 12, no. 20, 10301 | Abstract: | The dewatering of foundation pits with a suspended waterproof curtain causes different groundwater drawdowns inside and outside the pit, resulting in the drawdown difference between the inside and outside the pit. Maintaining a groundwater drawdown difference between the inside and outside of a foundation pit can eliminate the adverse effects of dewatering on the surrounding environment. According to previous studies on unsteady flow, an analytical solution of the groundwater drawdown with a suspended waterproof curtain under unsteady flow has been proposed. The analytical solution of unsteady flow and the formula of groundwater drawdown difference with a suspended waterproof curtain were validated by comparing pumping tests and finite-element method (FEM), in which a good agreement was observed. The magnitude of the drawdown difference generally represents the extent of surrounding groundwater affected by groundwater drawdown inside the pit. This paper also investigated the effects of sensitivity parameters on the drawdown difference for minimizing the effect of surrounding environment. During the process of dewatering with a suspended waterproof curtain, the groundwater drawdown (Sh) should not exceed the length of the waterproof curtain (L), and the optimal radius of foundation pit (Rw) and length of waterproof curtain (L) were found, i.e., Rw/H0 = 0.781 and L/H0 = 0.813 (H0 is 32 m). Beyond these values, the drawdown difference tends to be stable. The drawdown difference is also significantly affected by the dewatering time. When t < 48 h, the groundwater drawdown difference decreases rapidly; when t > 48 h, the groundwater drawdown difference stabilizes. | Keywords: | Analytical method Drawdown difference Foundation pit dewatering Phreatic aquifer Suspended waterproof curtain |
Publisher: | MDPI AG | Journal: | Applied sciences | EISSN: | 2076-3417 | DOI: | 10.3390/app122010301 | Rights: | © 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). The following publication Yang, K., Xu, C., Chi, M., & Wang, P. (2022). Analytical Analysis of the Groundwater Drawdown Difference Induced by Foundation Pit Dewatering with a Suspended Waterproof Curtain. Applied Sciences, 12(20), 10301 is available at https://doi.org/10.3390/app122010301. |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
applsci-12-10301.pdf | 5.41 MB | Adobe PDF | View/Open |
Page views
4
Citations as of Apr 14, 2025
Downloads
3
Citations as of Apr 14, 2025

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.