Title: Analytical analysis of the groundwater drawdown difference induced by foundation pit dewatering with a suspended waterproof curtain
Authors: Yang, K
Xu, C
Chi, M
Wang, P 
Issue Date: Oct-2022
Source: Applied sciences, Oct. 2022, v. 12, no. 20, 10301
Abstract: The dewatering of foundation pits with a suspended waterproof curtain causes different groundwater drawdowns inside and outside the pit, resulting in the drawdown difference between the inside and outside the pit. Maintaining a groundwater drawdown difference between the inside and outside of a foundation pit can eliminate the adverse effects of dewatering on the surrounding environment. According to previous studies on unsteady flow, an analytical solution of the groundwater drawdown with a suspended waterproof curtain under unsteady flow has been proposed. The analytical solution of unsteady flow and the formula of groundwater drawdown difference with a suspended waterproof curtain were validated by comparing pumping tests and finite-element method (FEM), in which a good agreement was observed. The magnitude of the drawdown difference generally represents the extent of surrounding groundwater affected by groundwater drawdown inside the pit. This paper also investigated the effects of sensitivity parameters on the drawdown difference for minimizing the effect of surrounding environment. During the process of dewatering with a suspended waterproof curtain, the groundwater drawdown (Sh) should not exceed the length of the waterproof curtain (L), and the optimal radius of foundation pit (Rw) and length of waterproof curtain (L) were found, i.e., Rw/H0 = 0.781 and L/H0 = 0.813 (H0 is 32 m). Beyond these values, the drawdown difference tends to be stable. The drawdown difference is also significantly affected by the dewatering time. When t < 48 h, the groundwater drawdown difference decreases rapidly; when t > 48 h, the groundwater drawdown difference stabilizes.
Keywords: Analytical method
Drawdown difference
Foundation pit dewatering
Phreatic aquifer
Suspended waterproof curtain
Publisher: MDPI AG
Journal: Applied sciences 
EISSN: 2076-3417
DOI: 10.3390/app122010301
Rights: © 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
The following publication Yang, K., Xu, C., Chi, M., & Wang, P. (2022). Analytical Analysis of the Groundwater Drawdown Difference Induced by Foundation Pit Dewatering with a Suspended Waterproof Curtain. Applied Sciences, 12(20), 10301 is available at https://doi.org/10.3390/app122010301.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
applsci-12-10301.pdf5.41 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

4
Citations as of Apr 14, 2025

Downloads

3
Citations as of Apr 14, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.