Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/111601
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Health Technology and Informatics-
dc.creatorChen, Z-
dc.creatorChambara, N-
dc.creatorLo, X-
dc.creatorLiu, SYW-
dc.creatorGunda, ST-
dc.creatorHan, X-
dc.creatorYing, MTC-
dc.date.accessioned2025-03-03T06:02:40Z-
dc.date.available2025-03-03T06:02:40Z-
dc.identifier.issn1355-008X-
dc.identifier.urihttp://hdl.handle.net/10397/111601-
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.rights© The Author(s) 2024en_US
dc.rightsThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.en_US
dc.rightsThe following publication Chen, Z., Chambara, N., Lo, X. et al. Improving the diagnostic strategy for thyroid nodules: a combination of artificial intelligence-based computer-aided diagnosis system and shear wave elastography. Endocrine 87, 744–757 (2025) is available at https://doi.org/10.1007/s12020-024-04053-2.en_US
dc.subjectComputer-aided diagnosisen_US
dc.subjectShear wave elastographyen_US
dc.subjectThyroid noduleen_US
dc.subjectUltrasounden_US
dc.titleImproving the diagnostic strategy for thyroid nodules : a combination of artificial intelligence-based computer-aided diagnosis system and shear wave elastographyen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage744-
dc.identifier.epage757-
dc.identifier.volume87-
dc.identifier.issue2-
dc.identifier.doi10.1007/s12020-024-04053-2-
dcterms.abstractPurpose: Thyroid nodules are highly prevalent in the general population, posing a clinical challenge in accurately distinguishing between benign and malignant cases. This study aimed to investigate the diagnostic performance of different strategies, utilizing a combination of a computer-aided diagnosis system (AmCAD) and shear wave elastography (SWE) imaging, to effectively differentiate benign and malignant thyroid nodules in ultrasonography.-
dcterms.abstractMethods: A total of 126 thyroid nodules with pathological confirmation were prospectively included in this study. The AmCAD was utilized to analyze the ultrasound imaging characteristics of the nodules, while the SWE was employed to measure their stiffness in both transverse and longitudinal thyroid scans. Twelve diagnostic patterns were formed by combining AmCAD diagnosis and SWE values, including isolation, series, parallel, and integration. The diagnostic performance was assessed using the receiver operating characteristic curve and area under the curve (AUC). Sensitivity, specificity, accuracy, missed malignancy rate, and unnecessary biopsy rate were also determined.-
dcterms.abstractResults: Various diagnostic schemes have shown specific advantages in terms of diagnostic performance. Overall, integrating AmCAD with SWE imaging in the transverse scan yielded the most favorable diagnostic performance, achieving an AUC of 72.2% (95% confidence interval (CI): 63.0–81.5%), outperforming other diagnostic schemes. Furthermore, in the subgroup analysis of nodules measuring <2 cm or 2–4 cm, the integrated scheme consistently exhibited promising diagnostic performance, with AUCs of 74.2% (95% CI: 61.9–86.4%) and 77.4% (95% CI: 59.4–95.3%) respectively, surpassing other diagnostic schemes. The integrated scheme also effectively addressed thyroid nodule management by reducing the missed malignancy rate to 9.5% and unnecessary biopsy rate to 22.2%.-
dcterms.abstractConclusion: The integration of AmCAD and SWE imaging in the transverse thyroid scan significantly enhances the diagnostic performance for distinguishing benign and malignant thyroid nodules. This strategy offers clinicians the advantage of obtaining more accurate clinical diagnoses and making well-informed decisions regarding patient management.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationEndocrine, Feb. 2025, v. 87, no. 2, p. 744-757-
dcterms.isPartOfEndocrine-
dcterms.issued2025-02-
dc.identifier.scopus2-s2.0-85205895051-
dc.identifier.eissn1559-0100-
dc.description.validate202503 bcch-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_TAen_US
dc.description.fundingSourceOthersen_US
dc.description.fundingTextHong Kong Polytechnic Universityen_US
dc.description.pubStatusPublisheden_US
dc.description.TASpringer Nature (2024)en_US
dc.description.oaCategoryTAen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
s12020-024-04053-2.pdf1.57 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

8
Citations as of Apr 14, 2025

Downloads

3
Citations as of Apr 14, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.