dc.rightsThis article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Wang, C., & Hong, J. (2023). Numerical investigation of airborne transmission in low-ceiling rooms under displacement ventilation. Physics of Fluids, 35(2) and may be found at https://doi.org/10.1063/5.0137354.en_US
dc.titleNumerical investigation of airborne transmission in low-ceiling rooms under displacement ventilationen_US
dc.typeJournal/Magazine Articleen_US
dc.description.otherinformationAuthor name used in this publication: 王畅畅en_US
dc.description.otherinformationAuthor name used in this publication: 洪家荣en_US
dc.identifier.spage023321-1-
dc.identifier.epage023321-23-
dc.identifier.volume35-
dc.identifier.issue2-
dc.identifier.doi10.1063/5.0137354-
dcterms.abstractThis study employs computational fluid dynamics (CFD) simulations to evaluate the risk of airborne transmission of COVID-19 in low-ceiling rooms, such as elevator cabins, under mechanical displacement ventilation. The simulations take into account the effects of the human body’s thermal environment and respiratory jet dynamics on the transmission of pathogens. The results of the study are used to propose a potential mitigation strategy based on ventilation thermal control to reduce the risk of airborne transmission in these types of enclosed indoor spaces. Our findings demonstrate that as the ventilation rate (Qv) increases, the efficiency of removing airborne particles (εp) initially increases rapidly, reaches a plateau (εp,c) at a critical ventilation rate (Qc), and subsequently increases at a slower rate beyond Qc. The Qc for low-ceiling rooms is lower compared to high-ceiling rooms due to the increased interaction between the thermal plume generated by the occupants or infectors and the ventilation. Further analysis of the flow and temperature fields reveals that εp is closely linked to the thermal stratification fields, as characterized by the thermal interface height and temperature gradient. When Qv < Qc, hT,20.7 < him (him is the height of infector’s mouth) and aerosol particles are injected into the upper warm layer. As Qv increases, the hti also increases following the 3/5 law, which helps displace the particles out of the room, resulting in a rapid increase of εp. However, when Qv > Qc, hT,20.7 > him and aerosol particles are injected into the lower cool layer. The hti deviates from 3/5 law and increases at a much slower rate, causing an aerosol particle lockup effect and the εp to plateau. In addition, as the Qc increases, the local flow recirculation above the infector head is also enhanced, which leads to the trapping of more particles in that area, contributing to the slower increase in εp. The simulations also indicate that the location of infector relative to ventilation inlet/outlet affects Qc and εp,c with higher Qc and lower εp,c observed when infector is in a corner due to potential formation of a local hot spot of high infection risk when infector is near the ventilation inlet. In conclusion, based on the simulations, we propose a potential ventilation thermal control strategy, by adjusting the ventilation temperature, to reduce the risk of airborne transmission in low-ceiling rooms. Our findings indicate that the thermal environment plays a critical role in the transmission of airborne diseases in confined spaces.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationPhysics of fluids, Feb. 2023, v. 35, no. 2, 023321, p. 023321-1 - 023321-23-
dcterms.isPartOfPhysics of fluids-
dcterms.issued2023-02-
dc.identifier.scopus2-s2.0-85148676560-
dc.identifier.eissn1089-7666-
dc.identifier.artn023321-
dc.description.validate202502 bcch-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_Othersen_US
dc.description.fundingSourceOthersen_US
dc.description.fundingTextChina Scholarship Council (CSC)en_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryVoR alloweden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
023321_1_online.pdf8.93 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

5
Citations as of Apr 14, 2025

Downloads

2
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

13
Citations as of Dec 19, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.