Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/111144
PIRA download icon_1.1View/Download Full Text
Title: Control of supersonic compression corner flow using a plasma actuator
Authors: Chen, Z 
Hao, J 
Wen, CY 
Issue Date: Jul-2022
Source: Physics of fluids, July 2022, v. 34, no. 7, 073605, p. 073605-1 - 073605-14
Abstract: The control performance of a pulsed nanosecond dielectric barrier discharge (NSDBD) plasma actuator with varying pulse voltages and locations on a supersonic compression corner is studied using experiments and numerical simulations. The compression corner with a flat plate length of 60 mm and a ramp angle of 10° under laminar flow separation is experimentally investigated in a Ludwieg wind tunnel under a unit Reynolds number of 7.8 × 106 m−1 and Mach number of 4. The plasma actuators are placed either upstream or downstream of the separation point, extending in the spanwise direction. The Schlieren technique is used to visualize the shock wave interaction and estimate the propagation speed of the induced shock by the plasma actuator. For the numerical simulations, a one-zone inhomogeneous phenomenological plasma model is adopted to predict key discharge parameters and simulate the fast-heating region. The results show that the reduction of separation bubble length is up to 17% and 45%, respectively, in the cases of upstream and downstream of the separation point under a high applied voltage of 50 kV. The evolution of the flow structures is examined to reveal the underlying control mechanism. The results indicate that the high-speed external fluid is entrained into the original separation region after NSDBD activation upstream of the separation point, resulting in flow reattachment upstream of the corner. The entrained fluid with high momentum compels the main separation to move downstream, accompanied by the fragmentation of the original shear layer. Furthermore, the suppression of the separation region is more effective when the plasma actuator is installed close to the separation region and in the first 200 μs during one pulse, providing a good suggestion for the actuation frequency and installed location.
Publisher: AIP Publishing LLC
Journal: Physics of fluids 
ISSN: 1070-6631
EISSN: 1089-7666
DOI: 10.1063/5.0096511
Rights: © 2022 Author(s). Published under an exclusive license by AIP Publishing.
This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Chen, Z., Hao, J., & Wen, C.-Y. (2022). Control of supersonic compression corner flow using a plasma actuator. Physics of Fluids, 34(7) and may be found at https://doi.org/10.1063/5.0096511.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
073605_1_online.pdf10.17 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

7
Citations as of Apr 14, 2025

Downloads

4
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

17
Citations as of Dec 19, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.