Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/110903
| Title: | Validity and reliability of automated treadmill six-minute walk test in patients entering exercise-based cardiac rehabilitation | Authors: | Nevelikova, M Dosbaba, F Pepera, G Felsoci, M Batalikova, K Su, JJ Batalik, L |
Issue Date: | 2023 | Source: | Annals of medicine, 2023, v. 55, no. 2, 2304664 | Abstract: | Introduction: The six-minute walk test (6MWT) is a well-established tool for assessing submaximal functional capacity for cardiac patients, but space limitations challenge its implementation. Treadmill-based (TR) 6MWT is a promising alternative, but it requires patients to complete a familiarization test to adapt treadmill speed regulation. With the advancement of sensors, it is possible to automatically control speed for individual patients and thus overcome the space limitation or the speed control difficulty on the treadmill for each patient. Methods: This study investigated the validity and interchangeability of automated speed TR6MWT and standard hallway (HL) 6MWT. Eighteen patients were assessed at baseline of the 12-week cardiac rehabilitation program. Fourteen of them were assessed after rehabilitation. All patients performed three TR6MWTs and three HL6MWTs at baseline and one of each test after the program. Results: Patients well tolerated the TR6MWT. There was a strong correlation between both test methods (r = 0.79). However, patients performed significantly better in HL6MWT (514.8m +/- 59.7m) than in TR6MWT (447.2 +/- 79.1m) with 95% CI, 40.4-94.6m, p < 0.05. Both tests showed high test-retest reliability (intraclass correlation coefficient of 0.86). The TR6MWT showed a valuable comparison of the effect of the cardiac rehabilitation program (20% increase, effect size 1.1) even though it is not interchangeable with the HL6MWT. Conclusion: The automated speed TR6MWT appears to be an acceptable tool with adequate validity, reliability, and responsiveness for assessing functional capacity in patients utilizing cardiac rehabilitation programs. |
Keywords: | Six minute walk test Cardiac rehabilitation Automatized treadmill Functional capacity Technology-assisted assessment |
Publisher: | Taylor & Francis | Journal: | Annals of medicine | ISSN: | 0785-3890 | EISSN: | 1365-2060 | DOI: | 10.1080/07853890.2024.2304664 | Rights: | © 2024 The Author(s). Published by informa UK limited, trading as Taylor & francis Group This is an open Access article distributed under the terms of the creative commons Attribution license (http://creativecommons.org/licenses/by/4.0/), which permits unrestricteduse, distribution, and reproduction in any medium, provided the original work is properly cited. The terms on which this article has been published allow the posting of theAccepted Manuscript in a repository by the author(s) or with their consent. The following publication Nevelikova, M., Dosbaba, F., Pepera, G., Felsoci, M., Batalikova, K., Su, J. J., & Batalik, L. (2023). Validity and reliability of automated treadmill six-minute walk test in patients entering exercise-based cardiac rehabilitation. Annals of Medicine, 55(2), 2304664 is available at https://dx.doi.org/10.1080/07853890.2024.2304664. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Nevelikova_Validity_Reliability_Automated.pdf | 1.79 MB | Adobe PDF | View/Open |
Page views
65
Citations as of Apr 14, 2025
Downloads
57
Citations as of Apr 14, 2025
SCOPUSTM
Citations
3
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
3
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



