Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/110653
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Biomedical Engineering-
dc.creatorSong, Y-
dc.creatorCen, X-
dc.creatorSun, D-
dc.creatorBálint, K-
dc.creatorWang, Y-
dc.creatorChen, H-
dc.creatorGao, S-
dc.creatorBíró, I-
dc.creatorZhang, M-
dc.creatorGu, Y-
dc.date.accessioned2024-12-27T06:27:35Z-
dc.date.available2024-12-27T06:27:35Z-
dc.identifier.urihttp://hdl.handle.net/10397/110653-
dc.language.isoenen_US
dc.publisherNature Publishing Groupen_US
dc.rightsThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.en_US
dc.rights© The Author(s) 2024en_US
dc.rightsThe following publication Song, Y., Cen, X., Sun, D. et al. Curved carbon-plated shoe may further reduce forefoot loads compared to flat plate during running. Sci Rep 14, 13215 (2024) is available at https://doi.org/10.1038/s41598-024-64177-3.en_US
dc.titleCurved carbon-plated shoe may further reduce forefoot loads compared to flat plate during runningen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume14-
dc.identifier.doi10.1038/s41598-024-64177-3-
dcterms.abstractUsing a curved carbon-fiber plate (CFP) in running shoes may offer notable performance benefit over flat plates, yet there is a lack of research exploring the influence of CFP geometry on internal foot loading during running. The objective of this study was to investigate the effects of CFP mechanical characteristics on forefoot biomechanics in terms of plantar pressure, bone stress distribution, and contact force transmission during a simulated impact peak moment in forefoot strike running. We employed a finite element model of the foot-shoe system, wherein various CFP configurations, including three stiffnesses (stiff, stiffer, and stiffest) and two shapes (flat plate (FCFP) and curved plate (CCFP)), were integrated into the shoe sole. Comparing the shoes with no CFP (NCFP) to those with CFP, we consistently observed a reduction in peak forefoot plantar pressure with increasing CFP stiffness. This decrease in pressure was even more notable in a CCFP demonstrating a further reduction in peak pressure ranging from 5.51 to 12.62%, compared to FCFP models. Both FCFP and CCFP designs had a negligible impact on reducing the maximum stress experienced by the 2nd and 3rd metatarsals. However, they greatly influenced the stress distribution in other metatarsal bones. These CFP designs seem to optimize the load transfer pathway, enabling a more uniform force transmission by mainly reducing contact force on the medial columns (the first three rays, measuring 0.333 times body weight for FCFP and 0.335 for CCFP in stiffest condition, compared to 0.373 in NCFP). We concluded that employing a curved CFP in running shoes could be more beneficial from an injury prevention perspective by inducing less peak pressure under the metatarsal heads while not worsening their stress state compared to flat plates.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationScientific reports, 2024, v. 14, 13215-
dcterms.isPartOfScientific reports-
dcterms.issued2024-
dc.identifier.scopus2-s2.0-85195365508-
dc.identifier.pmid38851842-
dc.identifier.eissn2045-2322-
dc.identifier.artn13215-
dc.description.validate202412 bcch-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_Scopus/WOSen_US
dc.description.fundingSourceRGCen_US
dc.description.fundingSourceOthersen_US
dc.description.fundingTextZhejiang Provincial Natural Science Foundation of China for Distinguished Young Scholars; Zhejiang Provincial Key Research and Development Program of China; Zhejiang Provincial Natural Science Foundation; Zhejiang Rehabilitation Medical Association Scientific Research Special Fund; Research Academy of Medicine Combining Sports, Ningbo; Project of NINGBO Leading Medical & Health Discipline; Ningbo Natural Science Foundation; Public Welfare Science & Technology Project of Ningbo, China; Shenzhen Research Funden_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryCCen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
s41598-024-64177-3.pdf1.5 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

36
Citations as of Apr 14, 2025

Downloads

7
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

20
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

21
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.