Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/110324
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorSchool of Professional Education and Executive Development-
dc.creatorTam, WS-
dc.creatorYip, J-
dc.creatorFang, C-
dc.creatorYick, KL-
dc.creatorNg, SP-
dc.date.accessioned2024-12-03T03:33:55Z-
dc.date.available2024-12-03T03:33:55Z-
dc.identifier.urihttp://hdl.handle.net/10397/110324-
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.rights© 2024 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).en_US
dc.rightsThe following publication Tam, W. S., Yip, J., Fang, C., Yick, K. L., & Ng, S. P. (2024). An optimal de Quervain's tenosynovitis splint with ergonomic thumb support and evenly distributed pressure. Heliyon, 10(4), e26330 is available at https://dx.doi.org/10.1016/j.heliyon.2024.e26330.en_US
dc.subjectSplinten_US
dc.subjectDe quervain 'S tenosynovitisen_US
dc.subjectAngles of handen_US
dc.subjectFinite element modelen_US
dc.subjectPressure distributionen_US
dc.titleAn optimal de Quervain's tenosynovitis splint with ergonomic thumb support and evenly distributed pressureen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume10-
dc.identifier.issue4-
dc.identifier.doi10.1016/j.heliyon.2024.e26330-
dcterms.abstractSplinting is a conventional treatment for de Quervain's tenosynovitis (dQt). However, existing splints have problems such as excessive thermal discomfort and poor fit, which have been pointed out in previous studies. This study proposes a new functional splint consisting of both hard and soft materials with the aim of providing wear comfort with a good fit and sufficient stability of the injured hand. Thumb support of the splint is an important component that controls and protects the affected thumb. To develop an ergonomically shaped thumb support, 16 participants with dQt were recruited for three-dimensional (3D) scanning of their hands. The angles of the wrist and the curvature of the thumb were measured using computer software, and the results were used as a reference for the design of the prototype supports. Excessive pressure on particular regions, such as bony areas, may cause discomfort or pain. To ensure the wear comfort of the proposed splint, a finite element model (FEM) was built to simulate the wear process of the splint and hence to predict the pressure distribution exerted from the splint onto the hand of the wearer. The simulated results show that the pressure is evenly distributed over the hand, indicating that patients are likely to wear the proposed splint comfortably during their treatment period.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationHeliyon, 29 Feb. 2024, v. 10, no. 4, e26330-
dcterms.isPartOfHeliyon-
dcterms.issued2024-02-29-
dc.identifier.isiWOS:001194021900001-
dc.identifier.pmid38420402-
dc.identifier.eissn2405-8440-
dc.identifier.artne26330-
dc.description.validate202412 bcrc-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_Scopus/WOSen_US
dc.description.fundingSourceOthersen_US
dc.description.fundingTextHong Kong Polytechnic Universityen_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryCCen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
1-s2.0-S2405844024023612-main.pdf7.5 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

21
Citations as of Apr 14, 2025

Downloads

6
Citations as of Apr 14, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.