Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/110150
PIRA download icon_1.1View/Download Full Text
Title: Comparative study of eclipse and RayStation multi-criteria optimization-based prostate radiotherapy treatment planning quality
Authors: Wong, JYK 
Leung, VWS 
Hung, RHM
Ng, CKC
Issue Date: Mar-2024
Source: Diagnostics, Mar. 2024, v. 14, no. 5, 465
Abstract: Multi-criteria optimization (MCO) function has been available on commercial radiotherapy (RT) treatment planning systems to improve plan quality; however, no study has compared Eclipse and RayStation MCO functions for prostate RT planning. The purpose of this study was to compare prostate RT MCO plan qualities in terms of discrepancies between Pareto optimal and final deliverable plans, and dosimetric impact of final deliverable plans. In total, 25 computed tomography datasets of prostate cancer patients were used for Eclipse (version 16.1) and RayStation (version 12A) MCO-based plannings with doses received by 98% of planning target volume having 76 Gy prescription (PTV76 D98%) and 50% of rectum (rectum D50%) selected as trade-off criteria. Pareto optimal and final deliverable plan discrepancies were determined based on PTV76 D98% and rectum D50% percentage differences. Their final deliverable plans were compared in terms of doses received by PTV76 and other structures including rectum, and PTV76 homogeneity index (HI) and conformity index (CI), using a t-test. Both systems showed discrepancies between Pareto optimal and final deliverable plans (Eclipse: −0.89% (PTV76 D98%) and −2.49% (Rectum D50%); RayStation: 3.56% (PTV76 D98%) and −1.96% (Rectum D50%)). Statistically significantly different average values of PTV76 D98%, HI and CI, and mean dose received by rectum (Eclipse: 76.07 Gy, 0.06, 1.05 and 39.36 Gy; RayStation: 70.43 Gy, 0.11, 0.87 and 51.65 Gy) are noted, respectively (p < 0.001). Eclipse MCO-based prostate RT plan quality appears better than that of RayStation.
Keywords: Cancer
Gleason score
Organs at risk
Pareto front
Pareto surface
Prostate-specific antigen
Radiation therapy
Target volume
Toxicity
Trade-off
Publisher: MDPI AG
Journal: Diagnostics 
EISSN: 2075-4418
DOI: 10.3390/diagnostics14050465
Rights: Copyright: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
The following publication Wong JYK, Leung VWS, Hung RHM, Ng CKC. Comparative Study of Eclipse and RayStation Multi-Criteria Optimization-Based Prostate Radiotherapy Treatment Planning Quality. Diagnostics. 2024; 14(5):465 is available at https://doi.org/10.3390/diagnostics14050465.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
diagnostics-14-00465-v2.pdf903.45 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

26
Citations as of Apr 14, 2025

Downloads

11
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

1
Citations as of Apr 24, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.