Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/110050
Title: The overall performance of a novel semi-transparent photovoltaic window with passive radiative cooling coating – a comparative study
Authors: Wang, W
Yang, H 
Xiang, C
Issue Date: Aug-2024
Source: Energy and buildings, 15 Aug. 2024, v. 317, 114433
Abstract: Semi-transparent photovoltaic (STPV) glazing is a promising building integrated photovoltaic (BIPV) technology for converting traditional windows into on-site energy-producing building components. Besides electricity generation, there is also an urgent demand to enhance the thermal management of STPV glazing. Passive radioactive cooling paint is an emerging nanomaterials technology that shows great potential to reduce the painted surface temperature. Aiming to further promote the PV window’s energy efficiency, this study designed and investigated a novel coated semi-transparent photovoltaic (CSTPV) glazing supplemented with highly transparent passive radiative cooling coating. In addition, the STPV/CSTPV’s impacts on indoor visual environments were investigated, especially on the rarely studied aspect of interior colour rendering performance. This paper employs a combination of numerical simulation and experimental measurements to comprehensively assess these innovative glass systems in terms of electricity generation, thermal performance, daylighting efficiency, and the impact of color on the indoor environment. The results indicate that the CSTPV windows can significantly reduce the heat gain rate by about 15 % and achieve excellent electricity generation, with an annual output approximately 3 % higher than that of STPV windows. Despite the radiative cooling coating, CSTPV glazing maintains a level of daylight illumination comparable to that of STPV glazing, with glare levels remaining within acceptable limits. Furthermore, the study emphasizes the effects of CSTPV and STPV on the indoor Color Rendering Index (CRI) and Correlated Color Temperature (CCT) performance. All samples measured have CCT values within the range of neutral light, and CRI values exceeding 96, demonstrating satisfactory high-quality indoor lighting conditions. This research shows that CSTPV and STPV glass technologies not only significantly enhance the energy efficiency of buildings but also provide a scientific foundation for sustainable development in architectural design.
Graphical abstract: [Figure not available: see fulltext.]
Keywords: Building integrated photovoltaics
Color rendering index
Passive radiative cooling
Semi-transparent PV
Solar energy
Publisher: Elsevier BV
Journal: Energy and buildings 
ISSN: 0378-7788
EISSN: 1872-6178
DOI: 10.1016/j.enbuild.2024.114433
Rights: © 2024 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/).
The following publication Wang, W., Yang, H., & Xiang, C. (2024). The overall performance of a novel semi-transparent photovoltaic window with passive radiative cooling coating – A comparative study. Energy and Buildings, 317, 114433 is available at https://doi.org/10.1016/j.enbuild.2024.114433.
Appears in Collections:Journal/Magazine Article

Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.