Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/109254
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Rehabilitation Sciences | - |
dc.creator | Zhao, JL | - |
dc.creator | Chen, PM | - |
dc.creator | Ng, SSM | - |
dc.creator | Mao, YR | - |
dc.creator | Huang, DF | - |
dc.date.accessioned | 2024-10-03T08:17:28Z | - |
dc.date.available | 2024-10-03T08:17:28Z | - |
dc.identifier.uri | http://hdl.handle.net/10397/109254 | - |
dc.language.iso | en | en_US |
dc.publisher | Frontiers Research Foundation | en_US |
dc.rights | © 2023 Zhao, Chen, Ng, Mao and Huang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (http://creativecommons.org/licenses/by/4.0/). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. | en_US |
dc.rights | The following publication Zhao J-L, Chen P-M, Ng SSM, Mao Y-R and Huang D-F (2023) Translation and concurrent validity, sensitivity and specificity of Chinese version of Short Orientation Memory Concentration Test in people with a first cerebral infarction. Front. Hum. Neurosci. 17:977078 is available at https://doi.org/10.3389/fnhum.2023.977078. | en_US |
dc.subject | Cognition | en_US |
dc.subject | Rehabilitation | en_US |
dc.subject | Sensitivity | en_US |
dc.subject | Short Orientation Memory Concentration Test (SOMC) | en_US |
dc.subject | Specificity | en_US |
dc.subject | Stroke | en_US |
dc.subject | Validity | en_US |
dc.title | Translation and concurrent validity, sensitivity and specificity of Chinese version of Short Orientation Memory Concentration Test in people with a first cerebral infarction | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.identifier.volume | 17 | - |
dc.identifier.doi | 10.3389/fnhum.2023.977078 | - |
dcterms.abstract | Purpose: This study aimed to translate the English version of the Short Orientation-Memory-Concentration (SOMC) test into a Chinese version, denoted the C-SOMC test, and to investigate the concurrent validity, sensitivity, and specificity of the C-SOMC test against a longer and widely used screening instrument in people with a first cerebral infarction. | - |
dcterms.abstract | Methods: An expert group translated the SOMC test into Chinese using a forward–backward procedure. Eighty-six participants (67 men and 19 women, mean age = 59.31 ± 11.57 years) with a first cerebral infarction were enrolled in this study. The validity of the C-SOMC test was determined using the Chinese version of Mini Mental State Examination (C-MMSE) as the comparator. Concurrent validity was determined using Spearman’s rank correlation coefficients. Univariate linear regression was used to analyze items’ abilities to predict the total score on the C-SOMC test and the C-MMSE score. The area under the receiver operating characteristic curve (AUC) was used to demonstrate the sensitivity and specificity of the C-SOMC test at various cut-off values distinguishing cognitive impairment from normal cognition. | - |
dcterms.abstract | Results: The total score for the C-SOMC test and the score for item 1 on this test exhibited moderate-to-good correlations with the C-MMSE score, with respective ρ-values of 0.636 and 0.565 (P < 0.001). The scores for each of items 2, 4, 5, 6, and 7 yielded fair correlations with C-MMSE score, with ρ-value from 0.272 to 0.495 (P < 0.05). The total score on the C-SOMC test and the item score were good predictors (adjusted R2 = 0.049 to 0.615) of the C-MMSE score, and six items were good predictors (adjusted R2 = 0.134 to 0.795) of the total score. The AUC was 0.92 for the C-SOMC test. A cut-off of 17/18 on the C-SOMC test gave optimal performance: correct classification of 75% of participants, with 75% sensitivity and 87.9% specificity. | - |
dcterms.abstract | Conclusion: The C-SOMC test demonstrated good concurrent validity, sensitivity and specificity in a sample of people with a first cerebral infarction, demonstrating that it could be used to screen for cognitive impairment in stroke patients. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | Frontiers in human neuroscience, 2023, v. 17, 977078 | - |
dcterms.isPartOf | Frontiers in human neuroscience | - |
dcterms.issued | 2023 | - |
dc.identifier.scopus | 2-s2.0-85162050363 | - |
dc.identifier.eissn | 1662-5161 | - |
dc.identifier.artn | 977078 | - |
dc.description.validate | 202410 bcch | - |
dc.description.oa | Version of Record | en_US |
dc.identifier.FolderNumber | OA_Scopus/WOS | en_US |
dc.description.fundingSource | Others | en_US |
dc.description.fundingText | National Key Research and Development Program of China; 5010 Planning Project of Sun Yat-sen University of China; National Natural Science Foundation of China; Medical Scientific Research Foundation of Guangdong Province | en_US |
dc.description.pubStatus | Published | en_US |
dc.description.oaCategory | CC | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
fnhum-17-977078.pdf | 979.01 kB | Adobe PDF | View/Open |
Page views
35
Citations as of Nov 24, 2024
Downloads
13
Citations as of Nov 24, 2024
SCOPUSTM
Citations
2
Citations as of Nov 21, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.