Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/108831
| Title: | Comparative study of plan robustness for breast radiotherapy : volumetric modulated arc therapy plans with robust optimization versus manual flash approach | Authors: | Chan, RCK Ng, CKC Hung, RHM Li, YTY Tam, YTY Wong, BYL Yu, JCK Leung, VWS |
Issue Date: | Nov-2023 | Source: | Diagnostics, Nov. 2023, v. 13, no. 22, 3395 | Abstract: | A previous study investigated robustness of manual flash (MF) and robust optimized (RO) volumetric modulated arc therapy plans for breast radiotherapy based on five patients in 2020 and indicated that the RO was more robust than the MF, although the MF is still current standard practice. The purpose of this study was to compare their plan robustness in terms of dose variation to clinical target volume (CTV) and organs at risk (OARs) based on a larger sample size. This was a retrospective study involving 34 female patients. Their plan robustness was evaluated based on measured volume/dose difference between nominal and worst scenarios (ΔV/ΔD) for each CTV and OARs parameter, with a smaller difference representing greater robustness. Paired sample t-test was used to compare their robustness values. All parameters (except CTV ΔD98%) of the RO approach had smaller ΔV/ΔD values than those of the MF. Also, the RO approach had statistically significantly smaller ΔV/ΔD values (p < 0.001–0.012) for all CTV parameters except the CTV ΔV95% and ΔD98% and heart ΔDmean. This study’s results confirm that the RO approach was more robust than the MF in general. Although both techniques were able to generate clinically acceptable plans for breast radiotherapy, the RO could potentially improve workflow efficiency due to its simpler planning process. | Keywords: | Cancer Chest wall displacement Dosimetry Error Organs at risk Radiation dose Radiation therapy Skin flash Target volume Uncertainty |
Publisher: | MDPI AG | Journal: | Diagnostics | EISSN: | 2075-4418 | DOI: | 10.3390/diagnostics13223395 | Rights: | © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). The following publication Chan RCK, Ng CKC, Hung RHM, Li YTY, Tam YTY, Wong BYL, Yu JCK, Leung VWS. Comparative Study of Plan Robustness for Breast Radiotherapy: Volumetric Modulated Arc Therapy Plans with Robust Optimization versus Manual Flash Approach. Diagnostics. 2023; 13(22):3395 is available at https://doi.org/10.3390/diagnostics13223395. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| diagnostics-13-03395.pdf | 2.95 MB | Adobe PDF | View/Open |
Page views
80
Citations as of Nov 10, 2025
Downloads
82
Citations as of Nov 10, 2025
SCOPUSTM
Citations
1
Citations as of Dec 19, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



