Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108534
PIRA download icon_1.1View/Download Full Text
Title: Revolutionary auxetic intravascular medical stents for angioplasty applications
Authors: Sadegh, Ebrahimi, M
Noruzi, M
Hamzehei, R
Etemadi, E 
Hashemi, R
Issue Date: Nov-2023
Source: Materials and design, Nov. 2023, v. 235, 112393
Abstract: Due to the significant mortality rate associated with atherosclerosis-induced cardiovascular disease, the utilization of advanced intravascular stents with superior mechanical performance is imperative for the restoration of obstructed arteries. This study proposes novel auxetic medical stents that aim to enhance critical parameters of biomedical stents. This includes load-bearing capacity, expanded opening percentage, and reduced recoil percentage. On this matter, the missing rib auxetic unit cell has been considered and geometrically modified to achieve these objectives. Two-dimensional (2D) metamaterials were fabricated through additive manufacturing technique and subjected to experimental testing. Then, finite element analysis (FEA) was employed to gain comprehensive insights into the mechanical behaviour of the proposed medical stents. Remarkably, an excellent correlation was observed between the FEA and experimental results, validating the high precision of the analysis. The findings reveal that the stents classified as “E-category” exhibit the highest final opening percentage while concurrently demonstrating the lowest recoil percentage. The base stent exhibited a relatively high recoil percentage of 15.56%, indicating a significant amount of recoil or spring-back after deformation. In contrast, the modified “E-category” stent displayed a substantially lower recoil percentage of 1.62%. This notable reduction in recoil percentage indicates that the modifications made to the rib-unit cells had a significant and beneficial effect on the stent's recoil behaviour and minimizing potential damage to arterial tissue during stent deployment (angioplasty) and balloon pressure. The modified design likely enhances the stent's ability to maintain its shape and resist recoil, making it more effective and reliable in its intended application. Additionally, more aspects of biomedical stents such as foreshortening, and dog-boning of the modified missing rib stents were meticulously examined through FEA.
Keywords: 3D printing
Angioplasty
Artery damage
Auxetic stents
Load bearing capacity
Metamaterials
Recoil percentage
Publisher: Elsevier Ltd
Journal: Materials and design 
ISSN: 0264-1275
EISSN: 1873-4197
DOI: 10.1016/j.matdes.2023.112393
Rights: © 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
The following publication Sadegh Ebrahimi, M., Noruzi, M., Hamzehei, R., Etemadi, E., & Hashemi, R. (2023). Revolutionary auxetic intravascular medical stents for angioplasty applications. Materials & Design, 235, 112393 is available at https://doi.org/10.1016/j.matdes.2023.112393.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
1-s2.0-S0264127523008080-main.pdf21.07 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

60
Citations as of Nov 10, 2025

Downloads

123
Citations as of Nov 10, 2025

SCOPUSTM   
Citations

53
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

52
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.