Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108282
PIRA download icon_1.1View/Download Full Text
Title: The air we breathe : numerical investigation of ventilation strategies to mitigate airborne dispersion of MERS-CoV in inpatient wards
Authors: Satheesan, MK 
Tsang, TW 
Wong, LT 
Mui, KW 
Issue Date: 29-Feb-2024
Source: Heliyon, 29 Feb. 2024, v. 10, no. 4, e26159
Abstract: Ventilation strategies for infection control in hospitals has been predominantly directed towards isolation rooms and operating theatres, with relatively less emphasis on perceived low risk spaces, such as general wards. Typically, the ventilation systems in general wards are intended to optimize patient thermal comfort and energy conservation. The emission of pathogens from exhalation activity, such as sneezing, by an undiagnosed infectious patient admitted to general wards, is a significant concern for infection outbreaks. However, the ventilation guidelines for general wards with respect to infection control are vague. This research article presents a numerical study on the effect of varying air change rates (3 h−1, 6 h−1, 9 h−1, 13 h−1) and exhaust flow rates (10%, 50% of supply air quantity) on the concentration of airborne pathogens in a mechanically ventilated general inpatient ward. The findings imply that the breathing zone directly above the source patient has the highest level of pathogen exposure, followed by the breathing zones at the bedside and adjacent patients close to the source patient. The dispersion of pathogens throughout the ward over time is also apparent. However, a key difference while adopting a lower ACH (3 h−1) and a higher ACH (13 h−1) in this study was that the latter had a significantly lower number of suspended pathogens in the breathing zone than the former. Thus, this research suggests high ventilation rates for general wards, contrary to current ventilation standards. In addition, combining a higher air change rate (13 h−1) with a high exhaust flow rate (50% of supply air) through a local exhaust grille dramatically reduced suspended pathogens within the breathing zone, further mitigating the risk of pathogen exposure for ward users. Therefore, this study presents an effective ventilation technique to dilute and eliminate airborne infectious pathogens, minimizing their concentration and the risk of infection.
Keywords: Airborne dispersion
Computational fluid dynamics
Infection control
Nosocomial infection
Open ward cubicle
Ventilation
Publisher: Elsevier Ltd
Journal: Heliyon 
EISSN: 2405-8440
DOI: 10.1016/j.heliyon.2024.e26159
Rights: © 2024 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
The following publication Satheesan, M. K., Tsang, T. W., Wong, L. T., & Mui, K. W. (2024). The air we breathe: Numerical investigation of ventilation strategies to mitigate airborne dispersion of MERS-CoV in inpatient wards. Heliyon, 10(4), e26159 is available at https://doi.org/10.1016/j.heliyon.2024.e26159.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
1-s2.0-S240584402402190X-main.pdf15.27 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

61
Citations as of Apr 14, 2025

Downloads

21
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

3
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

2
Citations as of Mar 27, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.