Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108234
PIRA download icon_1.1View/Download Full Text
Title: Shear wave trajectory detection in ultra-fast M-mode images for liver fibrosis assessment : a deep learning-based line detection approach
Authors: Wang, X 
Liu, B 
Wu, C 
Huang, Z 
Zhou, Y
Wu, X 
Zheng, Y 
Issue Date: Aug-2024
Source: Ultrasonics, Aug. 2024, v. 142, 107358
Abstract: Stiffness measurement using shear wave propagation velocity has been the most common non-invasive method for liver fibrosis assessment. The velocity is captured through a trace recorded by transient ultrasonographic elastography, with the slope indicating the velocity of the wave. However, due to various factors such as noise and shear wave attenuation, detecting shear wave trajectory on wave propagation maps is a challenging task. In this work, we made the first attempt to use deep learning methods for shear wave trajectory detection on wave propagation maps. Specifically, we adopted five deep learning models in this task and evaluated them by using a well-acknowledged metric based on EA-Angular-Score (EAA) and task-specific metric based on Young s-Score (Ys) in the line-detection field. Furthermore, we proposed an end-to-end framework based on a Transformer and Hough transform, named Transformer-enhanced Hough Transform (TEHT). It took a wave propagation map as input image and directly output the slope of the shear wave trajectory. The framework extracts multi-scale local features from wave propagation maps, employs a deformable attention mechanism for feature fusion, identifies the target line using the Hough transform’s voting mechanism, and calculates the contribution of each scale through channel attention. Wave propagation maps from 68 patients were utilized in this study, with manual annotation performed by a rater who was trained as a radiologist, serving as the reference value. The evaluation revealed that the SLNet model exhibited F-measure of EA and Ys values as 40.33 % and 40.72 %, respectively, while the TEHT model showed F-measure of EA and Ys values as 80.96 % and 98.00 %, respectively. TEHT yielded significantly better performance than other deep learning models. Moreover, TEHT demonstrated strong concordance with the gold standard, yielding R2 values of 0.967 and 0.968 for velocity and liver stiffness, respectively. The present study therefore suggests the application of the TEHT model for assessing liver fibrosis owing to its superiority among the five deep learning models.
Keywords: Deep learning
Line detection
Liver fibrosis
Transformer
Transient ultrasound elastography
Publisher: Elsevier BV
Journal: Ultrasonics 
ISSN: 0041-624X
EISSN: 1874-9968
DOI: 10.1016/j.ultras.2024.107358
Rights: © 2024 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
The following publication Wang, X., Liu, B., Wu, C., Huang, Z., Zhou, Y., Wu, X., & Zheng, Y. (2024). Shear wave trajectory detection in ultra-fast M-mode images for liver fibrosis assessment: A deep learning-based line detection approach. Ultrasonics, 142, 107358 is available at https://doi.org/10.1016/j.ultras.2024.107358.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
1-s2.0-S0041624X24001203-main.pdf7.55 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

62
Citations as of Apr 14, 2025

Downloads

17
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

1
Citations as of Sep 12, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.