Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108232
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Biomedical Engineering-
dc.contributorResearch Institute for Smart Ageing-
dc.creatorHuang, Z-
dc.creatorLam, SK-
dc.creatorCheng, LK-
dc.creatorLin, Y-
dc.creatorZheng, Y-
dc.date.accessioned2024-07-29T09:10:22Z-
dc.date.available2024-07-29T09:10:22Z-
dc.identifier.urihttp://hdl.handle.net/10397/108232-
dc.language.isoenen_US
dc.publisherSpringerOpenen_US
dc.rights© The Author(s) 2024. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.en_US
dc.rightsThe following publication Huang, Z., Lam, S.K., Cheng, L.K. et al. Determining the ideal measurement site and respiratory condition for liver transient elastography: toward clinical practice standardization. Insights Imaging 15, 114 (2024) is available at https://doi.org/10.1186/s13244-024-01692-x.en_US
dc.subjectIntercostal imagingen_US
dc.subjectLiver elastographyen_US
dc.subjectMeasurement guidelineen_US
dc.subjectMeasurement protocolen_US
dc.subjectUltrasound elastographyen_US
dc.titleDetermining the ideal measurement site and respiratory condition for liver transient elastography : toward clinical practice standardizationen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume15-
dc.identifier.doi10.1186/s13244-024-01692-x-
dcterms.abstractObjectives: Liver transient elastography (TE) has been endorsed by the WHO as the first-line diagnostic tool for liver diseases. Although unreliable and invalid results caused by intercostal space (ICS)-associated factors (including excessive subcutaneous fat and a narrow ICS relative to the transducer size) and operator inexperience are not uncommon, no standard guidelines for ideal probe placement are currently available. Herein, we conducted a prospective observational study to identify an ideal measurement site and respiratory condition for TE by characterizing anatomical and biomechanical properties of the ICSs using ultrasound B-mode and elasticity imaging.-
dcterms.abstractMethods: Intercostal ultrasound was performed pointwise at four specific sites in 59 patients to simultaneously measure the width, stiffness, and skin‒liver capsule distance (SCD) of the ICSs over the liver, under end-inspiratory and end-expiratory conditions. Intersections between the 8th ICS and anterior axillary line, the 7th ICS and anterior axillary line, the 8th ICS and mid-axillary line, and the 7th ICS and mid-axillary line were defined as Sites 1 to 4, respectively.-
dcterms.abstractResults: Results indicated that Sites 2 and 3 presented greater intercostal width; Sites 3 and 4 displayed lower intercostal stiffness; Sites 2 and 3 exhibited a shorter SCD. The ICSs were significantly wider and stiffer at end-inspiration. Additionally, the liver was more easily visualized at Sites 1 and 3.-
dcterms.abstractConclusion: We recommend Site 3 for TE probe placement owing to its greater width, lower stiffness, and smaller abdominal wall thickness. Performing TE at end-inspiration is preferred to minimize transducer-rib interferences. This study paves the way toward a standardized TE examination procedure.-
dcterms.abstractCritical relevance statement: A standardized measurement protocol for WHO-recommended liver TE was first established to improve the success and efficiency of the examination procedure.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationInsights into imaging, 2024, v. 15, 114-
dcterms.isPartOfInsights into imaging-
dcterms.issued2024-
dc.identifier.scopus2-s2.0-85192986884-
dc.identifier.pmid38734997-
dc.identifier.eissn1869-4101-
dc.identifier.artn114-
dc.description.validate202407 bcch-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumbera3096en_US
dc.identifier.SubFormID49609en_US
dc.description.fundingSourceOthersen_US
dc.description.fundingTextResearch Institute for Smart Ageing of the Hong Kong Polytechnic University (1-CD5B)en_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryCCen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
s13244-024-01692-x.pdf1.69 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

105
Citations as of Nov 10, 2025

Downloads

22
Citations as of Nov 10, 2025

SCOPUSTM   
Citations

1
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

1
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.