Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108131
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorSchool of Professional Education and Executive Development-
dc.contributorDepartment of Building Environment and Energy Engineering-
dc.creatorZhang, Y-
dc.creatorZhang, H-
dc.creatorYang, H-
dc.creatorChen, Y-
dc.creatorLeung, CW-
dc.date.accessioned2024-07-25T04:25:48Z-
dc.date.available2024-07-25T04:25:48Z-
dc.identifier.urihttp://hdl.handle.net/10397/108131-
dc.language.isoenen_US
dc.publisherMolecular Diversity Preservation International (MDPI)en_US
dc.rights© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).en_US
dc.rightsThe following publication Zhang, Y.; Zhang, H.; Yang, H.; Chen, Y.; Leung, C.W. Optimization of the Liquid Desiccant Cooling Systems in Hot and Humid Areas. Sustainability 2023, 15, 13511 is available at https://doi.org/10.3390/su151813511.en_US
dc.subjectIndirect evaporative coolingen_US
dc.subjectLiquid desiccant dehumidificationen_US
dc.subjectMulti-objective optimizationen_US
dc.subjectMulti-parameter analysisen_US
dc.titleOptimization of the liquid desiccant cooling systems in hot and humid areasen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume15-
dc.identifier.issue18-
dc.identifier.doi10.3390/su151813511-
dcterms.abstractAir-conditioning systems in hot and humid regions account for over 50% of total energy usage. Integrating an indirect evaporative cooling ((Formula presented.)) and a liquid desiccant dehumidifier ((Formula presented.)) as the liquid desiccant cooling system ((Formula presented.)) presents an energy-saving and emission-reducing solution to replace traditional mechanical vapor compression refrigeration ((Formula presented.)) systems. This integration overcomes the regional limitations of IEC in hot and humid areas. The newly developed (Formula presented.) uses exhaust air as the working air source and solar energy as the heat source for desiccant solution regeneration. This study aims to develop an empirical model for the outlet parameters of the (Formula presented.), propose an optimization strategy for its operating parameters, and assess the potential and energy performance through parameter analysis and multifactor optimization. By conducting sensitivity analysis and optimizing six critical parameters based on a response surface model ((Formula presented.)), the system outlet temperature, relative humidity, and coefficient of performance ((Formula presented.)) are improved as the optimization objectives. The regional capability is demonstrated in three selected hot and humid cities. The results indicate that the (Formula presented.) can significantly increase the (Formula presented.) by 57.3%. Additionally, it can meet the dehumidification demand when operating with 25% of the air extracted in the (Formula presented.) during months with high humidity and temperature. This study will facilitate the application of (Formula presented.) and (Formula presented.) technologies, guide the design and operation scheme of the system, and promote energy-saving and emission-reducing solutions in hot and humid regions.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationSustainability, Sept. 2023, v. 15, no. 18, 13511-
dcterms.isPartOfSustainability-
dcterms.issued2023-09-
dc.identifier.scopus2-s2.0-85172867589-
dc.identifier.eissn2071-1050-
dc.identifier.artn13511-
dc.description.validate202407 bcwh-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumbera3091-n13en_US
dc.description.fundingSourceRGCen_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryCCen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
sustainability-15-13511-v2.pdf7.03 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

45
Citations as of Apr 14, 2025

Downloads

31
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

7
Citations as of Sep 12, 2025

WEB OF SCIENCETM
Citations

2
Citations as of Nov 14, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.