Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/108093
Title: Characteristics of droplets emission immediately around mouth during dental treatments
Authors: Xing, C
Ai, Z 
Liu, Z
Mak, CM 
Wong, HM
Issue Date: 15-Jan-2024
Source: Building and environment, 15 Jan. 2024, v. 248, 111066
Abstract: Control measures aiming for removing droplets generated during dental treatments have been attracted increasing attention after COVID-19 pandemic, but the emission characteristics of droplets around the source (namely, the mouth) have still not been fully understood. The present study investigated experimentally the emission characteristics of droplets around mouth during typical dental treatments. A manikin being treated by portable dental instruments simulated the dental treatments, while the laser light scattering technique and particle image velocimetry (PIV) technique were employed to perform the measurements. The peak mass fraction of droplets occurs around the droplet size from 20 μ diameter less than 200 droplets ( μ m to 100 μ m, while the mass fraction of droplets with the m accounts for over 80 %. By fitting with the Rosin-Rammler equation, the mean size of ◦ to 83 ◦ d) are 54.96 and 98.93, and the size distribution parameter (n) are 1.35 and 1.58, respectively, for the process of air-powder-polishing and ultrasonic scaling. The dominant emission direction of droplets is towards the dummy’ head and chest. The emitted droplets formed approximately a cone shape, and its angle varied from 25 for different conditions. The maximum velocity of droplets at the location near the dummy’s mouth exceeds 1.0 m/s for most conditions. The injecting flow rate and treated tooth position are the major factors influencing the emission direction, angle, and velocity. It is expected that the results can further increase our understanding of emission characteristics of droplets and provide accurate initial conditions for CFD simulations.
Keywords: Droplets
Laser light scattering
Particle image velocimetry
Powder-jet-handpieces
Ultrasonic scaling instrument
Publisher: Elsevier BV
Journal: Building and environment 
ISSN: 0360-1323
EISSN: 1873-684X
DOI: 10.1016/j.buildenv.2023.111066
Appears in Collections:Journal/Magazine Article

Open Access Information
Status embargoed access
Embargo End Date 2026-01-15
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

95
Citations as of Nov 10, 2025

SCOPUSTM   
Citations

14
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

13
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.