Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/107662
| Title: | Reconstruction of multi-phase parametric maps in 4D-magnetic resonance fingerprinting (4D-MRF) by optimization of local T1 and T2 sensitivities | Authors: | Wong, YL Li, T Liu, C Lee, HFV Cheung, LYA Hui, ESK Cao, P Cai, J |
Issue Date: | Jul-2024 | Source: | Medical physics, July 2024, v. 51, no. 7, p. 4721-4735 | Abstract: | Background: Time-resolved magnetic resonance fingerprinting (MRF), or 4D-MRF, has been demonstrated its feasibility in motion management in radiotherapy (RT). However, the prohibitive long acquisition time is one of challenges of the clinical implementation of 4D-MRF. The shortening of acquisition time causes data insufficiency in each respiratory phase, leading to poor accuracies and consistencies of the predicted tissues’ properties of each phase. Purpose: To develop a technique for the reconstruction of multi-phase parametric maps in four-dimensional magnetic resonance fingerprinting (4D-MRF) through the optimization of local T1 and T2 sensitivities. Methods: The proposed technique employed an iterative optimization to tailor the data arrangement of each phase by manipulation of inter-phase frames, such that the T1 and T2 sensitivities, which were quantified by the modified Minkowski distance, of the truncated signal evolution curve was maximized. The multi-phase signal evolution curves were modified by sliding window reconstruction and inter-phase frame sharing (SWIFS). Motion correction (MC) and dot product matching were sequentially performed on the modified signal evolution and dictionary to reconstruct the multi-parametric maps. The proposed technique was evaluated by numerical simulations using the extended cardiac-torso (XCAT) phantom with regular and irregular breathing patterns, and by in vivo MRF data of three health volunteers and six liver cancer patients acquired at a 3.0 T scanner. Results: In simulation study, the proposed SWIFS approach achieved the overall mean absolute percentage error (MAPE) of 8.62% ± 1.59% and 16.2% ± 3.88% for the eight-phases T1 and T2 maps, respectively, in the sagittal view with irregular breathing patterns. In contrast, the overall MAPE of T1 and T2 maps generated by the conventional approach with multiple MRF repetitions were 22.1% ± 11.0% and 30.8% ± 14.9%, respectively. For in-vivo study, the predicted mean T1 and T2 of liver by the proposed SWIFS approach were 795 ms ± 38.9 ms and 58.3 ms ± 11.7 ms, respectively. Conclusions: Both simulation and in vivo results showed that the approach empowered by T1 and T2 sensitivities optimization and sliding window under the shortened acquisition of MRF had superior performance in the estimation of multi-phase T1 and T2 maps as compared to the conventional approach with oversampling of MRF data. |
Keywords: | 4D Imaging abdominal MRI liver cancer motion management MR fingerprinting |
Publisher: | Wiley-Blackwell Publishing, Inc. | Journal: | Medical physics | ISSN: | 0094-2405 | EISSN: | 2473-4209 | DOI: | 10.1002/mp.17001 | Rights: | © 2024 American Association of Physicists in Medicine. This is the peer reviewed version of the following article: Wong YL, Li T, Liu C, et al. Reconstruction of multi-phase parametric maps in 4D-magnetic resonance fingerprinting (4D-MRF) by optimization of local T1 and T2 sensitivities. Med Phys. 2024; 51: 4721–4735, which has been published in final form at https://doi.org/10.1002/mp.17001. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. This article may not be enhanced, enriched or otherwise transformed into a derivative work, without express permission from Wiley or by statutory rights under applicable legislation. Copyright notices must not be removed, obscured or modified. The article must be linked to Wiley’s version of record on Wiley Online Library and any embedding, framing or otherwise making available the article or pages thereof by third parties from platforms, services and websites other than Wiley Online Library must be prohibited. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Wong_Reconstruction_Multi-phase_Parametric.pdf | Pre-Published version | 2.54 MB | Adobe PDF | View/Open |
Page views
53
Citations as of Apr 14, 2025
SCOPUSTM
Citations
1
Citations as of Aug 29, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



