Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/107555
| Title: | Motion-resolved four-dimensional abdominal diffusion-weighted imaging using PROPELLER EPI (4D-DW-PROPELLER-EPI) | Authors: | Wang, L Li, T Cai, J Chang, HC |
Issue Date: | Dec-2023 | Source: | Magnetic resonance in medicine, Dec. 2023, v. 90, no. 6, p. 2454-2471 | Abstract: | Purpose: To develop a distortion-free motion-resolved four-dimensional diffusion-weighted PROPELLER EPI (4D-DW-PROPELLER-EPI) technique for benefiting clinical abdominal radiotherapy (RT). Methods: An improved abdominal 4D-DWI technique based on 2D diffusion-weighted PROPELLER-EPI (2D-DW-PROPELLER-EPI), termed 4D-DW-PROPELLER-EPI, was proposed to improve the frame rate of repeated data acquisition and produce distortion-free 4D-DWI images. Since the radial or PROPELLER sampling with golden-angle rotation can achieve an efficient k-space coverage with a flexible time-resolved acquisition, the golden-angle multi-blade acquisition was used in the proposed 4D-DW-PROPELLER-EPI to improve the performance of data sorting. A new k-space and blade (K-B) amplitude binning method was developed for the proposed 4D-DW-PROPELLER-EPI to optimize the number of blades and the k-space uniformity before performing conventional PROPELLER-EPI reconstruction, by using two metrics to evaluate the adequacy of the acquired data. The proposed 4D-DW-PROPELLER-EPI was preliminarily evaluated in both simulation experiments and in vivo experiments with varying frame rates and different numbers of repeated acquisition. Results: The feasibility of achieving distortion-free 4D-DWI images by using the proposed 4D-DW-PROPELLER-EPI technique was demonstrated in both digital phantom and healthy subjects. Evaluation of the 4D completeness metrics shows that the K-B amplitude binning method could simultaneously improve the acquisition efficiency and data reconstruction performance for 4D-DW-PROPELLER-EPI. Conclusion: 4D-DW-PROPELLER-EPI with K-B amplitude binning is an advanced technique that can provide distortion-free 4D-DWI images for resolving respiratory motion, and may benefit the application of image-guided abdominal RT. |
Keywords: | 4D-DWI Distortion-free images Golden angle K-B amplitude binning PROPELLER-EPI |
Publisher: | John Wiley & Sons, Inc. | Journal: | Magnetic resonance in medicine | ISSN: | 0740-3194 | EISSN: | 1522-2594 | DOI: | 10.1002/mrm.29802 | Rights: | © 2023 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine (http://creativecommons.org/licenses/by-nc-nd/4.0/). This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium,provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. The following publication Wang L, Li T, Cai J, Chang H-C. Motion-resolved four-dimensional abdominal diffusion-weighted imaging using PROPELLER EPI (4D-DW-PROPELLER-EPI). Magn Reson Med. 2023; 90: 2454-2471 is available at https://doi.org/10.1002/mrm.29802. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Wang_Motion-resolved_Four-dimensional_Abdominal.pdf | 8.25 MB | Adobe PDF | View/Open |
Page views
87
Citations as of Nov 10, 2025
Downloads
93
Citations as of Nov 10, 2025
SCOPUSTM
Citations
2
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
3
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



