Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/107496
Title: The ability of physical performance measures to identify fall risk in older adults living with dementia : a systematic review and meta-analysis
Authors: Chan, WLS 
Pin, TW 
Chan, JYH 
Siu, GCH 
Tsang, SMH 
Issue Date: 2024
Source: Journal of the American Medical Directors Association, Available online 19 June 2024, In Press, Uncorrected Proof, 105100, https://doi.org/10.1016/j.jamda.2024.105100
Abstract: Objectives: To determine whether physical performance measures commonly used in clinical settings can discriminate fallers from nonfallers and predict falls in older adults with dementia.
Design: Systematic review and meta-analysis.
Setting and Participants: Older adults with dementia residing in the community, hospitals, and residential care facilities.
Methods: MEDLINE, Embase, PsycINFO, CINAHL, SPORTDiscus, the Cochrane Library, and the PEDro databases were searched from inception until December 27, 2023 (PROSPERO registration number: CRD42022303670). Retrospective or prospective studies that evaluated the associations between physical performance measures and falls in older adults with dementia were included. A random effects model was used to calculate the standardized mean difference (SMD) and 95% CI for each physical performance measure between fallers and nonfallers. Sensitivity analyses were conducted on the longitudinal studies to determine the ability of physical performance measures to predict future falls.
Results: Twenty-eight studies were included in this review (n = 3542). The 5-time chair stand test [SMD = 0.23 (0.01, 0.45)], the Berg Balance Scale [SMD = −0.52 (–0.87, −0.17)], postural sway when standing on the floor [SMD = 0.25 (0.07, 0.43)] and on a foam surface [SMD = 0.45 (0.25, 0.66)], and the Short Physical Performance Battery total score [SMD = −0.46 (–0.66, −0.27)] could discriminate fallers from nonfallers. Sensitivity analyses showed that gait speed could predict future falls in longitudinal cohort studies [SMD = −0.29 (–0.49, −0.08)]. Subgroup analyses showed that gait speed [SMD = −0.21 (–0.38, −0.05)] and the Timed Up and Go test [SMD = 0.54 (0.16, 0.92)] could identify fallers staying in residential care facilities or hospitals.
Conclusions and Implications: The 5-time chair stand test, the Berg Balance Scale, postural sway when standing on the floor and a foam surface, and the Short Physical Performance Battery can be used to predict falls in older adults with dementia. Gait speed and the Timed Up and Go test can be used to predict falls in institutionalized older adults with dementia. Clinicians are recommended to use these physical performance measures to assess fall risk in older adults with dementia.
Keywords: Dementia
Discriminative ability
Falls
Outcome measures
Physical performance
Publisher: Elsevier Inc.
Journal: Journal of the American Medical Directors Association 
ISSN: 1525-8610
EISSN: 1525-8610
DOI: 10.1016/j.jamda.2024.105100
Appears in Collections:Journal/Magazine Article

Open Access Information
Status embargoed access
Embargo End Date 0000-00-00 (to be updated)
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

4
Citations as of Jun 30, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.