Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/107433
PIRA download icon_1.1View/Download Full Text
Title: Custom orthotic design by integrating 3D scanning and subject-specific FE modelling workflow
Authors: Peng, Y 
Wang, Y 
Zhang, Q
Chen, SF 
Zhang, M 
Li, G
Issue Date: Jul-2024
Source: Medical and biological engineering and computing, July 2024, v. 62, no. 7, p. 2059-2071
Abstract: The finite element (FE) foot model can help estimate pathomechanics and improve the customized foot orthoses design. However, the procedure of developing FE models can be time-consuming and costly. This study aimed to develop a subject-specific scaled foot modelling workflow for the foot orthoses design based on the scanned foot surface data. Six participants (twelve feet) were collected for the foot finite element modelling. The subject-specific surface-based finite element model (SFEM) was established by incorporating the scanned foot surface and scaled foot bone geometries. The geometric deviations between the scaled and the scanned foot surfaces were calculated. The SFEM model was adopted to predict barefoot and foot-orthosis interface pressures. The averaged distances between the scaled and scanned foot surfaces were 0.23 ± 0.09 mm. There was no significant difference for the hallux, medial forefoot, middle forefoot, midfoot, medial hindfoot, and lateral hindfoot, except for the lateral forefoot region (p = 0.045). The SFEM model evaluated slightly higher foot-orthoses interface pressure values than measured, with a maximum deviation of 7.1%. These results indicated that the SFEM technique could predict the barefoot and foot-orthoses interface pressure, which has the potential to expedite the process of orthotic design and optimization.
Keywords: Customized foot scaling
Finite element analysis
Foot orthosis
Foot–ankle joint
Publisher: Springer
Journal: Medical and biological engineering and computing 
ISSN: 0140-0118
EISSN: 1741-0444
DOI: 10.1007/s11517-024-03067-2
Rights: © The Author(s) 2024
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
The following publication Peng, Y., Wang, Y., Zhang, Q. et al. Custom orthotic design by integrating 3D scanning and subject-specific FE modelling workflow. Med Biol Eng Comput 62, 2059–2071 (2024) is available at https://doi.org/10.1007/s11517-024-03067-2.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
s11517-024-03067-2.pdf6.47 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

5
Citations as of Jun 30, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.