Title: | Non-wearable respiration monitoring based on Mach–Zehnder interferometer | Authors: | Li, K Xu, W Zhang, N Wang, K Yu, C Yu, C |
Issue Date: | 2017 | Source: | In Proceedings of 2017 Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR), 31 July 2017 - 04 August 2017, Singapore | Abstract: | A novel non-wearable respiration monitoring smart mat structure embedded with optical fiber sensor is proposed and experimentally investigated, which can effectively detect the breathing rate (BR) of human subjects in sleeping position. The sensing principle is mainly based on the Mach-Zehnder interferometer (MZI), and the fibers used are all common single mode fibers (SMFs) with 900-micron buffer jacket avoiding fragility in practical use. The monitoring system has the advantages of non-invasion, non-fragility, simple structure, high sensitivity, low cost, and anti-electromagnetic interference. | Keywords: | Mach-Zehnder interferometer (MZI) Non-wearable Optical fiber sensor Respiration |
Publisher: | Institute of Electrical and Electronics Engineers | ISBN: | 978-1-5090-6290-4 (Electronic) 978-1-5090-6291-1 (Print on Demand(PoD)) |
DOI: | 10.1109/CLEOPR.2017.8118820 | Description: | 2017 Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR), 31 July 2017 - 04 August 2017, Singapore | Rights: | ©2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The following publication K. Li, W. Xu, N. Zhan, K. Wan, C. Yu and C. Yu, "Non-wearable respiration monitoring based on Mach-Zehnder interferometer," 2017 Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR), Singapore, 2017 is available at https://doi.org/10.1109/CLEOPR.2017.8118820. |
Appears in Collections: | Conference Paper |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Yu_Non-Wearable_Respiration_Monitoring.pdf | Pre-Published version | 564.73 kB | Adobe PDF | View/Open |
Page views
1
Citations as of Jun 30, 2024
Downloads
1
Citations as of Jun 30, 2024
SCOPUSTM
Citations
7
Citations as of Jun 21, 2024
![](/image/google_scholar.jpg)
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.