Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/107240
PIRA download icon_1.1View/Download Full Text
Title: Non-wearable respiration monitoring based on Mach–Zehnder interferometer
Authors: Li, K
Xu, W
Zhang, N
Wang, K
Yu, C
Yu, C 
Issue Date: 2017
Source: In Proceedings of 2017 Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR), 31 July 2017 - 04 August 2017, Singapore
Abstract: A novel non-wearable respiration monitoring smart mat structure embedded with optical fiber sensor is proposed and experimentally investigated, which can effectively detect the breathing rate (BR) of human subjects in sleeping position. The sensing principle is mainly based on the Mach-Zehnder interferometer (MZI), and the fibers used are all common single mode fibers (SMFs) with 900-micron buffer jacket avoiding fragility in practical use. The monitoring system has the advantages of non-invasion, non-fragility, simple structure, high sensitivity, low cost, and anti-electromagnetic interference.
Keywords: Mach-Zehnder interferometer (MZI)
Non-wearable
Optical fiber sensor
Respiration
Publisher: Institute of Electrical and Electronics Engineers
ISBN: 978-1-5090-6290-4 (Electronic)
978-1-5090-6291-1 (Print on Demand(PoD))
DOI: 10.1109/CLEOPR.2017.8118820
Description: 2017 Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR), 31 July 2017 - 04 August 2017, Singapore
Rights: ©2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
The following publication K. Li, W. Xu, N. Zhan, K. Wan, C. Yu and C. Yu, "Non-wearable respiration monitoring based on Mach-Zehnder interferometer," 2017 Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR), Singapore, 2017 is available at https://doi.org/10.1109/CLEOPR.2017.8118820.
Appears in Collections:Conference Paper

Files in This Item:
File Description SizeFormat 
Yu_Non-Wearable_Respiration_Monitoring.pdfPre-Published version564.73 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

1
Citations as of Jun 30, 2024

Downloads

1
Citations as of Jun 30, 2024

SCOPUSTM   
Citations

7
Citations as of Jun 21, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.