Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/106939
| DC Field | Value | Language |
|---|---|---|
| dc.contributor | Photonics Research Centre | en_US |
| dc.contributor | Department of Electrical and Electronic Engineering | en_US |
| dc.creator | Guo, N | en_US |
| dc.creator | Gui, T | en_US |
| dc.creator | Jin, C | en_US |
| dc.creator | Wang, L | en_US |
| dc.creator | Tam, HY | en_US |
| dc.creator | Lu, C | en_US |
| dc.date.accessioned | 2024-06-07T00:59:00Z | - |
| dc.date.available | 2024-06-07T00:59:00Z | - |
| dc.identifier.isbn | 978-1-943580-42-2 | en_US |
| dc.identifier.uri | http://hdl.handle.net/10397/106939 | - |
| dc.description | CLEO: Science and Innovations 2018, San Jose, California United States, 13-18 May 2018 | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | Optica Publishing Group | en_US |
| dc.rights | © 2018 The Author(s) | en_US |
| dc.rights | The following publication N. Guo, T. Gui, C. Jin, L. Wang, H. Tam, and C. Lu, "Averaging-free Vector BOTDA assisted by a Reference Probe Lightwave," in Conference on Lasers and Electro-Optics, OSA Technical Digest (online) (Optica Publishing Group, 2018), paper SM3K.3 is available at https://doi.org/10.1364/CLEO_SI.2018.SM3K.3. | en_US |
| dc.title | Averaging-free vector BOTDA assisted by a reference probe lightwave | en_US |
| dc.type | Conference Paper | en_US |
| dc.identifier.doi | 10.1364/CLEO_SI.2018.SM3K.3 | en_US |
| dcterms.abstract | We propose and experimentally demonstrate an averaging-free vector BOTDA system, which enables both distributed Brillouin gain and Brillouin phase shift detection without trace averaging. A 4m spatial resolution over 18.3 km is realized. | en_US |
| dcterms.accessRights | open access | en_US |
| dcterms.bibliographicCitation | Conference on Lasers and Electro-Optics, OSA Technical Digest (online) (Optica Publishing Group, 2018), paper SM3K.3 | en_US |
| dcterms.issued | 2018 | - |
| dc.identifier.scopus | 2-s2.0-85048962139 | - |
| dc.relation.conference | Conference on Lasers and Electro-Optics [CLEO] | en_US |
| dc.identifier.artn | SM3K.3 | en_US |
| dc.description.validate | 202405 bcch | en_US |
| dc.description.oa | Version of Record | en_US |
| dc.identifier.FolderNumber | EIE-0481, EIE-0605 | - |
| dc.description.fundingSource | RGC | en_US |
| dc.description.fundingSource | Others | en_US |
| dc.description.fundingText | NSFC; PolyU | en_US |
| dc.description.pubStatus | Published | en_US |
| dc.identifier.OPUS | 20016591, 50576239 | - |
| dc.description.oaCategory | VoR allowed | en_US |
| Appears in Collections: | Conference Paper | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| cleo_si-2018-sm3k.3.pdf | 764.92 kB | Adobe PDF | View/Open |
Page views
97
Last Week
3
3
Last month
Citations as of Nov 9, 2025
Downloads
46
Citations as of Nov 9, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



