Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/106567
PIRA download icon_1.1View/Download Full Text
Title: A scanning spatial-wavenumber filter and PZT 2-D cruciform array based on-line damage imaging method of composite structure
Authors: Qiu, L
Liu, B
Yuan, S
Su, Z 
Ren, Y
Issue Date: 1-Sep-2016
Source: Sensors and actuators. A, Physical, 1 Sept 2016, v. 248, p. 62-72
Abstract: The spatial-wavenumber filtering technique of Lamb wave is gradually applied for damage inspection of composite structure in recent years because it is an effective approach to distinguish the wave propagating direction and mode. But for on-line damage monitoring of composite structure by using spatial-wavenumber filter, the problem is how to realize the spatial-wavenumber filtering of Lamb wave when the wavenumber response cannot be measured or modeled. This paper proposes a scanning spatial-wavenumber filter and piezoelectric sensor (referred to as PZT) 2-D cruciform array based on-line damage imaging method of composite structure. In this method, a 2-D cruciform array constructed by two linear PZT arrays is placed on composite structure permanently to acquire Lamb wave damage scattering signal on-line. For one linear PZT array, a scanning spatial-wavenumber filter which does not rely on any modeled or measured wavenumber response is designed to filter the damage scattering signal at a designed wavenumber bandwidth to give out a wavenumber-time image. Based on the image, the wavenumber of the damage scattering signal projecting at the array can be obtained. The same process can be also applied to the other linear PZT array to get the wavenumber projecting at that array direction. By combining with the two projection wavenumbers, the damage can be localized without blind angle. The method is validated on an aircraft composite oil tank of variable thickness. The validation results show that the damage direction estimation error is less than 2° and the damage distance estimation error is around 20 mm in the monitoring area of nearly 600 mm × 300 mm. It indicates an acceptable performance of the damage imaging method for complex composite structure.
Keywords: 2-D cruciform array
Composite structure
Damage imaging
Lamb wave
Spatial-wavenumber filter
Structural health monitoring
Publisher: Elsevier Ltd
Journal: Sensors and actuators. A, Physical 
ISSN: 0924-4247
EISSN: 1873-3069
DOI: 10.1016/j.sna.2016.04.062
Rights: © 2016 Elsevier B.V. All rights reserved.
© 2016. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Qiu, L., Liu, B., Yuan, S., Su, Z., & Ren, Y. (2016). A scanning spatial-wavenumber filter and PZT 2-D cruciform array based on-line damage imaging method of composite structure. Sensors and Actuators A: Physical, 248, 62-72 is available at https://doi.org/10.1016/j.sna.2016.04.062.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Su_Scanning_Spatial-Wavenumber_Filter.pdfPre-Published version729.3 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

10
Citations as of Jun 30, 2024

Downloads

4
Citations as of Jun 30, 2024

SCOPUSTM   
Citations

25
Citations as of Jun 27, 2024

WEB OF SCIENCETM
Citations

22
Citations as of Jun 27, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.