Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/106527
PIRA download icon_1.1View/Download Full Text
Title: Adhesion contact deformation in nanobridge tests
Authors: Gao, Y 
Shi, SQ 
Zhang, TY
Issue Date: 14-May-2017
Source: Nanoscale, 14 May 2017, v. 9, no. 18, p. 6033-6040
Abstract: An accurate grasp of the mechanical properties, especially Young's moduli, of one dimensional nanomaterials plays a crucial role in the design and safe service of flexible electronic devices and implanted biomedical sensors. Nanobridge tests are widely used in the characterization of the mechanical properties of nanowires. In these tests, an atomic force microscope (AFM), functioning as a test machine, exerts a force to bend a nanowire suspended across a trench or a hole with the two ends fixed on a template or substrate. Adhesion contact deformation occurs inevitably during nanobridge testing between the AFM tip and the tested sample, thereby underestimating the Young's modulus of the tested nanowire and causing a pseudo-size effect in the determined Young's modulus. The present work systematically investigates the adhesion contact deformation in nanobridge tests and provides an analytical approach to evaluate the contact deformation and to determine the Young's modulus. To illustrate the developed methodology, AFM nanobridge tests were conducted on gold nanowires (180–340 nm wide, 3.6–5.1 μm long and 90 nm thick). The results indicate that when the contact deformation was taken into consideration, the average Young's modulus increased by 4.63%. Guidelines for minimizing the impact of contact deformation in practical experiments are presented. Furthermore, the results provide insight into the probable causes of the variation in experimentally obtained size-dependencies of Young's moduli of nanowires.
Publisher: Royal Society of Chemistry
Journal: Nanoscale 
ISSN: 2040-3364
EISSN: 2040-3372
DOI: 10.1039/c7nr01038a
Rights: This journal is © The Royal Society of Chemistry 2017
This is the accepted manuscript of the following article: Gao, Y., Shi, S.-Q., & Zhang, T.-Y. (2017). Adhesion contact deformation in nanobridge tests. Nanoscale, 9(18), 6033-6040, which has been published in final form at https://doi.org/10.1039/C7NR01038A.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Shi_Adhesion_Contact_Deformation.pdfPre-Published version1.47 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

11
Citations as of Jun 30, 2024

SCOPUSTM   
Citations

6
Citations as of Jun 27, 2024

WEB OF SCIENCETM
Citations

8
Citations as of Jun 27, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.