Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/106515
PIRA download icon_1.1View/Download Full Text
Title: Robotic knot tying through a spatial trajectory with a visual servoing system
Authors: Lu, B 
Chu, HK 
Cheng, L 
Issue Date: 2017
Source: 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems, Vancouver, British Columbia, Canada, 24-28 September 2017, p. 5710-5716
Abstract: Robot assisted surgery has become increasingly popular with the rapid development of more sophisticated robotic systems. Nevertheless, there are still many tedious surgical tasks that remain to be performed manually by surgeons with high supervisions. One example is to tie a surgical knot during the surgery, which includes the processes of needle threading, suture looping, suture tail grasping and suture pulling. In this research, we present a new method for robotic suture looping process. This method is based on a spatial trajectory planning for the surgical instruments, where challenges such as suture slippage and potential collisions between the instruments could be eliminated. In contrast to conventional looping process, a dynamic control scheme is proposed to optimize the time and workspace required to complete the process. Vision information is incorporated in order to enable closed loop control of the robotic system with Linear Quadratic (LQ) controller. A series of experiments were conducted in order to examine the performance of the proposed control scheme and the results confirmed that surgical knots can be successfully tied robotically, offering new insights to the field of automated robotassisted surgery.
Publisher: Institute of Electrical and Electronics Engineers
ISBN: 978-1-5386-2683-2 (Print on Demand(PoD))
978-1-5386-2682-5 (Electronic)
978-1-5386-2681-8 (USB)
DOI: 10.1109/IROS.2017.8206461
Description: 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems, Vancouver, British Columbia, Canada, 24-28 September 2017
Rights: © 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
The following publication B. Lu, H. K. Chu and L. Cheng, "Robotic knot tying through a spatial trajectory with a visual servoing system," 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2017, pp. 5710-5716 is available at https://doi.org/10.1109/IROS.2017.8206461.
Appears in Collections:Conference Paper

Files in This Item:
File Description SizeFormat 
Lu_Robotic_Knot_Tying.pdfPre-Published version988.22 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

65
Last Week
5
Last month
Citations as of Nov 9, 2025

Downloads

79
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

6
Citations as of Dec 19, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.