Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/106010
PIRA download icon_1.1View/Download Full Text
Title: Identification of the critical depth-of-cut through a 2D image of the cutting region resulting from taper cutting of brittle materials
Authors: Gu, W
Zhu, Z 
Zhu, WL
Lu, L
To, S 
Xiao, G 
Issue Date: May-2018
Source: Measurement science and technology, May 2018, v. 29, no. 5, 55003
Abstract: An automatic identification method for obtaining the critical depth-of-cut (DoC) of brittle materials with nanometric accuracy and sub-nanometric uncertainty is proposed in this paper. With this method, a two-dimensional (2D) microscopic image of the taper cutting region is captured and further processed by image analysis to extract the margin of generated micro-cracks in the imaging plane. Meanwhile, an analytical model is formulated to describe the theoretical curve of the projected cutting points on the imaging plane with respect to a specified DoC during the whole cutting process. By adopting differential evolution algorithm-based minimization, the critical DoC can be identified by minimizing the deviation between the extracted margin and the theoretical curve. The proposed method is demonstrated through both numerical simulation and experimental analysis. Compared with conventional 2D- and 3D-microscopic-image-based methods, determination of the critical DoC in this study uses the envelope profile rather than the onset point of the generated cracks, providing a more objective approach with smaller uncertainty.
Keywords: Brittle material
Critical depth-of-cut
Diamond cutting
Differential evolution algorithm
Publisher: Institute of Physics Publishing
Journal: Measurement science and technology 
ISSN: 0957-0233
EISSN: 1361-6501
DOI: 10.1088/1361-6501/aaa519
Rights: © 2018 IOP Publishing Ltd
This is the Accepted Manuscript version of an article accepted for publication in Measurement Science and Technology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://www.doi.org/10.1088/1361-6501/aaa519.
This manuscript version is made available under the CC-BY-NC-ND 4.0 license (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Zhu_Identification_Critical_Depth-Of-Cut.pdfPre-Published version834.75 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

36
Citations as of Apr 28, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.