Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/105921
PIRA download icon_1.1View/Download Full Text
Title: Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography
Authors: Chan, CW 
Chow, SCC 
Kwok, MH 
Ngan, KCT 
Or, TH 
Gunda, ST 
Ying, M 
Issue Date: Apr-2023
Source: Ultrasonography, Apr. 2023, v. 42, no. 2, p. 214-226
Abstract: Purpose: Carotid vessel wall volume (VWV) measurement on three-dimensional ultrasonography (3DUS) outperforms conventional two-dimensional ultrasonography for carotid atherosclerosis evaluation. Although time-saving semi-automated algorithms have been introduced, their clinical availability remains limited due to a lack of validation, particularly an extensive reliability analysis. This study compared inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid VWV measurements on 3DUS.
Methods: Thirty-one 3DUS volume datasets were prospectively acquired from 20 healthy subjects, aged >18 years, without previous stroke, transient ischemic attack, or cardiovascular disease. Five observers segmented all volume datasets both manually and semi-automatically. The process was repeated five times. Reliability was expressed by the intraclass correlation coefficient, supplemented by the coefficient of variation.
Results: Carotid VWV measurements using the common carotid artery (CCA) were more reliable than those using the internal carotid artery (ICA) or external carotid artery (ECA) for both manual and semiautomated segmentation (manual segmentation, CCA: inter-observer, 0.935; intra-observer, 0.934 to 0.966; ICA: inter-observer, 0.784; intra-observer, 0.756 to 0.878; ECA: inter-observer, 0.732; intraobserver, 0.919 to 0.962; semi-automated segmentation, CCA: inter-observer, 0.986; intra-observer, 0.954 to 0.993; ICA: inter-observer, 0.977; intra-observer, 0.958 to 0.978; ECA: inter-observer, 0.966; intra-observer, 0.884 to 0.937). Total carotid VWV measurements by manual (inter-observer, 0.922; intra-observer, 0.927 to 0.961) and semi-automated segmentation (inter-observer, 0.987; intra-observer, 0.968 to 0.989) were highly reliable. Semi-automated segmentation showed higher reliability than manual segmentation for both individual and total carotid VWV measurements.
Conclusion: 3DUS carotid VWV measurements of the CCA are more reliable than measurements of the ICA and ECA. Total carotid VWV measurements are highly reliable. Semi-automated segmentation has higher reliability than manual segmentation.
Keywords: Carotid vessel wall volume
Manual segmentation
Reliability
Semi-automated segmentation
Three-dimensional ultrasound
Publisher: Korean Society of Ultrasound in Medicine
Journal: Ultrasonography 
ISSN: 2288-5919
EISSN: 2288-5943
DOI: 10.14366/usg.22123
Rights: Copyright © 2023 Korean Society of Ultrasound in Medicine (KSUM)
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
The following publication Chan CW, Chow SCC, Kwok MH, Ngan KCT, Or TH, Gunda ST, Ying M. Inter-observer and intra-observer reliability between manual segmentation and semi-automated segmentation for carotid vessel wall volume measurements on three-dimensional ultrasonography. Ultrasonography. 2023;42(2):214-226 is available at https://dx.doi.org/10.14366/usg.22123.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
usg-22123.pdf1.21 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

16
Citations as of Jun 30, 2024

Downloads

5
Citations as of Jun 30, 2024

SCOPUSTM   
Citations

1
Citations as of Jul 4, 2024

WEB OF SCIENCETM
Citations

1
Citations as of Jul 4, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.