Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/105415
PIRA download icon_1.1View/Download Full Text
Title: A proper sequence of dynamic alignment in transtibial prosthesis : insight through socket reaction moments
Authors: Hashimoto, H
Kobayashi, T 
Gao, F
Kataoka, M
Issue Date: 2023
Source: Scientific reports, 2023, v. 13, 458
Abstract: Dynamic alignment in prosthetic fitting is important because it affects the user’s stability, kinematics, and kinetics such as socket reaction moments. It is performed by tuning the spatial relationship between the transtibial prosthetic socket and the foot following sequential observational gait analysis in the three anatomical planes. However, the order of planes in which the adjustment should be performed is still unclear. To investigate the appropriate sequence of dynamic alignment adjustment, ten participants with transtibial amputation were asked to walk in different alignment conditions (flexion, extension, adduction, abduction; lateral, medial, anterior, and posterior translation of the socket, and plantarflexion, dorsiflexion, inversion, and eversion of the foot) to measure socket reaction moments in the out-of-planes (e.g., the effect of sagittal alignment on the coronal moment). A significant difference was found only among socket posterior translation, socket flexion, and baseline alignment in the coronal moment (P = 0.02). The results of the current and previous studies suggest that moments in the coronal plane are affected by alignment changes in all three planes, whereas moments in the sagittal plane are affected only by sagittal alignment changes. It is suggested that the procedure of alignment adjustments should be finalized in the coronal plane.
Publisher: Nature Publishing Group
Journal: Scientific reports 
EISSN: 2045-2322
DOI: 10.1038/s41598-023-27438-1
Rights: © The Author(s) 2023
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
The following publication Hashimoto, H., Kobayashi, T., Gao, F. et al. A proper sequence of dynamic alignment in transtibial prosthesis: insight through socket reaction moments. Sci Rep 13, 458 (2023) is available at https://doi.org/10.1038/s41598-023-27438-1.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
s41598-023-27438-1.pdf3.17 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

21
Citations as of Jul 7, 2024

Downloads

14
Citations as of Jul 7, 2024

SCOPUSTM   
Citations

2
Citations as of Jul 4, 2024

WEB OF SCIENCETM
Citations

2
Citations as of Jul 4, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.