Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/104952
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorSchool of Optometryen_US
dc.contributorResearch Centre for SHARP Visionen_US
dc.creatorWu, THYen_US
dc.creatorLau, HKCen_US
dc.creatorLai, CHYen_US
dc.creatorWong, RWLen_US
dc.creatorWong, AKWen_US
dc.creatorLam, AKCen_US
dc.date.accessioned2024-03-14T08:55:51Z-
dc.date.available2024-03-14T08:55:51Z-
dc.identifier.urihttp://hdl.handle.net/10397/104952-
dc.language.isoenen_US
dc.publisherNature Publishing Groupen_US
dc.rights© The Author(s) 2024en_US
dc.rightsThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.en_US
dc.rightsThe following publication Wu, T.H.Y., Lau, H.K.C., Lai, C.H.Y. et al. Effect of digital ocular massage on intraocular pressure and Schlemm’s canal dimensions. Sci Rep 14, 6112 (2024) is available at https://doi.org/10.1038/s41598-024-56748-1.en_US
dc.subjectAqueous humoren_US
dc.subjectIntraocular pressureen_US
dc.subjectOcular massageen_US
dc.subjectSchlemm’s canalen_US
dc.subjectTrabecular meshworken_US
dc.titleEffect of digital ocular massage on intraocular pressure and Schlemm’s canal dimensionsen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume14en_US
dc.identifier.doi10.1038/s41598-024-56748-1en_US
dcterms.abstractDigital ocular massage has been reported to temporarily lower intraocular pressure (IOP). This could be related to an enhanced aqueous humor outflow; however, the mechanism is not clearly understood. Using anterior segment optical coherence tomography, the Schlemm’s canal (SC) and trabecular meshwork (TM) can be imaged and measured. Here, 66 healthy adults underwent digital ocular massage for 10 min in their right eyes. The IOP and dimensions of the SC and TM were measured before and after ocular massage. All subjects demonstrated IOP reduction from 15.7 ± 2.5 mmHg at baseline to 9.6 ± 2.2 mmHg immediately after, and median of 11.6 mmHg 5-min after ocular massage (Friedman’s test, p < 0.001). There was significant change in SC area (median 10,063.5 μm2 at baseline to median 10,151.0 μm2 after ocular massage, Wilcoxon test, p = 0.02), and TM thickness (median 149.8 μm at baseline to 144.6 ± 25.3 μm after ocular massage, Wilcoxon test, p = 0.036). One-third of the subjects demonstrated collapse of the SC area (−2 to −52%), while two-thirds showed expansion of the SC area (2 to 168%). There were no significant changes in SC diameter (270.4 ± 84.1 μm vs. 276.5 ± 68.7 μm, paired t-test, p = 0.499), and TM width (733.3 ± 110.1 μm vs. 733.5 ± 111.6 μm, paired t-test, p = 0.988). Eyes with a higher baseline IOP demonstrated a greater IOP reduction (Pearson correlation coefficient r = −0.521, p < 0.001). Eyes with smaller SC area at baseline showed greater SC area expansion (Pearson correlation coefficient = −0.389, p < 0.001). Greater IOP reduction appeared in eyes with greater SC area expansion (Pearson correlation coefficient r = −0.306, p = 0.01). Association between change in IOP and change in TM thickness was not significant (Spearman’s ρ = 0.015, p = 0.902). Simple digital ocular massage is an effective method to lower IOP values, and change in the SC area was significantly associated with IOP changes.en_US
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationScientific reports, 2024, v. 14, 6112en_US
dcterms.isPartOfScientific reportsen_US
dcterms.issued2024-
dc.identifier.eissn2045-2322en_US
dc.identifier.artn6112en_US
dc.description.validate202403 bcchen_US
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumbera2645-
dc.identifier.SubFormID47997-
dc.description.fundingSourceOthersen_US
dc.description.fundingTextInnoHK initiative and the Hong Kong Special Administrative Region Governmenten_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryCCen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
s41598-024-56748-1.pdf2.13 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

58
Citations as of Oct 13, 2024

Downloads

11
Citations as of Oct 13, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.