Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/104928
PIRA download icon_1.1View/Download Full Text
Title: Paediatric norms for photopic electroretinogram testing based on a large cohort of Chinese preschool children
Authors: Chan, SS 
Choi, KY 
Chan, HHP 
Issue Date: 2024
Source: BMJ Open Ophthalmology, 2024, v. 9, no. 1, e001393
Abstract: Objective Full-field electroretinogram (ffERG) is an objective test to determine the electroretinal activities in response to light stimulation for investigating retinal physiology and diagnosing retinal diseases. This study aimed to establish a reference data set of photopic electroretinogram (ERG) of Chinese preschool children in Hong Kong to facilitate clinical and research studies.
Methods and analysis Preschool children aged 3–7 years with normal vision were recruited from local kindergartens. Eye examinations, including cycloplegic spherical equivalent refraction (SER), axial length (AL) and keratometry (K) measurements, were performed. ffERGs of the International Society for Clinical Electrophysiology of Vision (ISCEV) standard photopic flash and 30-Hz flicker protocols were measured using RETeval with Sensor Strip skin electrodes. ERG waveform characteristics were extracted, and relationships between ERG, age, SER, AL and K were evaluated.
Results A total of 479 children completed the measurements (mean age: 5.0±0.9 years, 45.5% female). Mean, 95% CIs, 5th–95th percentile range of the ERG parameters were reported. Age was positively associated with amplitudes of b-wave and 30-Hz flicker (p<0.01), but negatively associated with implicit times of b-wave and 30-Hz flicker (p<0.01). AL was significantly associated with all amplitudes of a-wave, b-wave and 30-Hz flicker (p≤0.01) and implicit time of both a-wave and 30-Hz flicker (p<0.05). K was positively associated only with 30-Hz flicker amplitude (p=0.01), and no association between all responses and SER.
Conclusion Reference data set of photopic ERG of Chinese preschool children was established. Cross-sectional investigations revealed associations between ERG, age, SER and AL, which were speculated to further implicate the role of retina in refractive error development.
Publisher: BMJ Group
Journal: BMJ Open ophthalmology 
EISSN: 2397-3269
DOI: 10.1136/bmjophth-2023-001393
Rights: © Author(s) (or their employer(s)) 2024. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.
This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
The following publication Chan SS, Choi KY, Chan HH. Paediatric norms for photopic electroretinogram testing based on a large cohort of Chinese preschool children. BMJ Open Ophthalmology 2024;9:e001393 is available at https://dx.doi.org/10.1136/bmjophth-2023-001393.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
e001393.full.pdf855.57 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

36
Citations as of Jul 7, 2024

Downloads

11
Citations as of Jul 7, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.