Title: | Simplified robustness assessment of steel framed structures under fire-induced column failure | Authors: | Jiang, B Li, GQ Yam, MCH |
Issue Date: | 25-Apr-2020 | Source: | Steel and composite structures, 25 Apr. 2020, v. 35, no. 2, p. 199-213 | Abstract: | This paper proposes a Global-Local Analysis Method (GLAM) to assess the progressive collapse of steel framed structures under fire-induced column failure. GLAM obtains the overall structural response by combining dynamic analysis of the heated column (local) with static analysis of the overall structure (global). Test results of two steel frames which explicitly consider the dynamic effect during fire-induced column failure were employed to validate the proposed GLAM. Results show that GLAM gives reasonable predictions to the test frames in terms of both whether to collapse and the displacement verse temperature curves. Besides, several case studies of a two-dimensional (2D) steel frame and a three-dimensional (3D) steel frame with concrete slabs were conducted by using GLAM. Results show that GLAM gives the same collapse predictions to the studied cases with nonlinear dynamic analysis of the whole structure model. Compared with nonlinear dynamic analysis of the whole structure model, GLAM saves approximately 70% and 99% CPU time for the cases of 2D and 3D steel frame, respectively. Results also show that the load level of a structure has notable effects on the restraint condition of a heated column in the structure. | Keywords: | Dynamic effect Fire-induced column failure Progressive collapse Robustness assessment method Steel framed structure |
Publisher: | Techno-Press | Journal: | Steel and composite structures | ISSN: | 1229-9367 | EISSN: | 1598-6233 | DOI: | 10.12989/scs.2020.35.2.199 | Rights: | Copyright © 2020 Techno-Press, Ltd. This is the accepted version of the following article: Jiang, B., Li, G. Q., & Yam, M. C. (2020). Simplified robustness assessment of steel framed structures under fire-induced column failure. Steel and Composite Structures, An International Journal, 35(2), 199-213, which has been published in https://doi.org/10.12989/scs.2020.35.2.199. |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Jiang_Simplified_Robustness_Assessment.pdf | 1.25 MB | Adobe PDF | View/Open |
Page views
63
Citations as of May 11, 2025
Downloads
32
Citations as of May 11, 2025
SCOPUSTM
Citations
12
Citations as of Jun 21, 2024
WEB OF SCIENCETM
Citations
13
Citations as of Jun 5, 2025

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.