Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/104672
PIRA download icon_1.1View/Download Full Text
Title: Simplified robustness assessment of steel framed structures under fire-induced column failure
Authors: Jiang, B 
Li, GQ
Yam, MCH 
Issue Date: 25-Apr-2020
Source: Steel and composite structures, 25 Apr. 2020, v. 35, no. 2, p. 199-213
Abstract: This paper proposes a Global-Local Analysis Method (GLAM) to assess the progressive collapse of steel framed structures under fire-induced column failure. GLAM obtains the overall structural response by combining dynamic analysis of the heated column (local) with static analysis of the overall structure (global). Test results of two steel frames which explicitly consider the dynamic effect during fire-induced column failure were employed to validate the proposed GLAM. Results show that GLAM gives reasonable predictions to the test frames in terms of both whether to collapse and the displacement verse temperature curves. Besides, several case studies of a two-dimensional (2D) steel frame and a three-dimensional (3D) steel frame with concrete slabs were conducted by using GLAM. Results show that GLAM gives the same collapse predictions to the studied cases with nonlinear dynamic analysis of the whole structure model. Compared with nonlinear dynamic analysis of the whole structure model, GLAM saves approximately 70% and 99% CPU time for the cases of 2D and 3D steel frame, respectively. Results also show that the load level of a structure has notable effects on the restraint condition of a heated column in the structure.
Keywords: Dynamic effect
Fire-induced column failure
Progressive collapse
Robustness assessment method
Steel framed structure
Publisher: Techno-Press
Journal: Steel and composite structures 
ISSN: 1229-9367
EISSN: 1598-6233
DOI: 10.12989/scs.2020.35.2.199
Rights: Copyright © 2020 Techno-Press, Ltd.
This is the accepted version of the following article: Jiang, B., Li, G. Q., & Yam, M. C. (2020). Simplified robustness assessment of steel framed structures under fire-induced column failure. Steel and Composite Structures, An International Journal, 35(2), 199-213, which has been published in https://doi.org/10.12989/scs.2020.35.2.199.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Jiang_Simplified_Robustness_Assessment.pdf1.25 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

63
Citations as of May 11, 2025

Downloads

32
Citations as of May 11, 2025

SCOPUSTM   
Citations

12
Citations as of Jun 21, 2024

WEB OF SCIENCETM
Citations

13
Citations as of Jun 5, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.