Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/103552
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Civil and Environmental Engineeringen_US
dc.creatorZhou, LRen_US
dc.creatorChen, Len_US
dc.creatorXia, Yen_US
dc.creatorKoo, KYen_US
dc.date.accessioned2023-12-20T07:14:52Z-
dc.date.available2023-12-20T07:14:52Z-
dc.identifier.issn1673-565Xen_US
dc.identifier.urihttp://hdl.handle.net/10397/103552-
dc.language.isoenen_US
dc.publisherZhejiang University Pressen_US
dc.rights© Zhejiang University and Springer-Verlag GmbH Germany, part of Springer Nature 2020en_US
dc.rightsThis version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use (https://www.springernature.com/gp/open-research/policies/accepted-manuscript-terms), but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: https://doi.org/10.1631/jzus.A1900490.en_US
dc.subjectLong-span suspension bridgeen_US
dc.subjectTemperature effecten_US
dc.subjectStatic responseen_US
dc.subjectVehicle loaden_US
dc.subjectField monitoringen_US
dc.titleTemperature-induced structural static responses of a long-span steel box girder suspension bridgeen_US
dc.typeJournal/Magazine Articleen_US
dc.description.otherinformationTitle on author's file: Analysis of the temperature-induced structural static properties of a long-span steel box-girder suspension bridgeen_US
dc.description.otherinformationTitle in Traditional Chinese: 大跨度鋼箱梁懸索橋溫度所致結構靜力響應en_US
dc.identifier.spage580en_US
dc.identifier.epage592en_US
dc.identifier.volume21en_US
dc.identifier.issue7en_US
dc.identifier.doi10.1631/jzus.A1900490en_US
dcterms.abstractTemperature is a significant load on bridges, particularly for long-span steel box girder bridges. This study investigates the temperature-induced static responses of a long-span suspension bridge under real service environmental conditions using numerical simulations and field measurements. Detailed 2D finite element (FE) models of a typical section for the box girder, main cable, hanger, tower column, and crossbeam are constructed. The thermal boundary conditions are determined strictly according to the surrounding environments of a typical sunny day and applied to the FE models. A transient heat-transfer analysis is performed and the time-dependent temperature and its distribution on the bridge are obtained. In addition, a fine, 3D FE model of the bridge is developed for a structural analysis. The calculated temperatures are applied to the 3D model and the temperature-induced structural responses are simulated. The simulated temperatures and the associated static responses have good agreement with the measured counterparts and support the numerical simulation method. The main cable and bridge deck make the greatest contributions to the temperature effects on the suspension bridge. The static responses of bridge caused by the design vehicle load are also calculated. The daily variation of the temperature-induced static responses is comparable with, even higher than, that of the design vehicle load.en_US
dcterms.abstract目的: 温度对大跨度桥梁的力学性能影响显著。针对大 跨度钢箱梁悬索桥,本文采用数值方法分析日温 度变化引起的结构静力响应,对比设计车荷载, 以评估温度静力效应的影响。en_US
dcterms.abstract创新点: 1. 基于数值方法对比大跨度悬索桥温度静力效应 与设计车荷载效应,评估温度效应的影响;2. 阐 明悬索桥主要构件温度效应对总体温度效应的 贡献及相互之间的影响。en_US
dcterms.abstract方法: 1. 建立现场环境和结构响应的结构健康监测系 统,并进行长期监测;2. 通过精细化有限元分析 方法实现桥梁温度荷载和温度效应的精准数值 计算。en_US
dcterms.abstract结论: 1. 温度对大跨度悬索桥跨中位移的影响明显,其 一天的变化约是设计车荷载位移的10%;箱型主 梁横向温差是导致桥面横向倾斜的主要因素。 2. 箱梁温度应力显著大于车荷载引起的应力;部 分次要构件的温度应力成为主要荷载效应。3. 主 缆竖向倾角越大,温度应力越大;吊杆温度效应 主要受其长度和两端相对变形的影响。4. 桥塔温 度效应不仅受其自身温度的影响,也会受到来自 主缆温度响应的较大影响。5. 本文结论是基于一 天温度变化的影响,而温度效应在更大时间尺度 上的影响会更为严重。en_US
dcterms.accessRightsopen accessen_US
dcterms.alternative大跨度钢箱梁悬索桥温度所致结构静力响应en_US
dcterms.bibliographicCitationJournal of Zhejiang University. Science A, July 2020, v. 21, no. 7, p. 580-592en_US
dcterms.isPartOfJournal of Zhejiang University. Science Aen_US
dcterms.issued2020-07-
dc.identifier.eissn1862-1775en_US
dc.description.validate202312 bcchen_US
dc.description.oaAccepted Manuscripten_US
dc.identifier.FolderNumberCEE-0824-
dc.description.fundingSourceSelf-fundeden_US
dc.description.pubStatusPublisheden_US
dc.identifier.OPUS26101935-
dc.description.oaCategoryGreen (AAM)en_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Xia_Analysis_Temperature-induced_Structural.pdfPre-Published version1.8 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

126
Citations as of May 11, 2025

Downloads

64
Citations as of May 11, 2025

SCOPUSTM   
Citations

14
Citations as of Jun 21, 2024

WEB OF SCIENCETM
Citations

18
Citations as of Jun 5, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.