Title: Energy factors of trilinear SDOF systems representing damage-control buildings with energy dissipation fuses subjected to near-fault earthquakes
Authors: Ke, K
Zhao, Q 
Yam, MCH 
Ke, S
Issue Date: Apr-2018
Source: Soil dynamics and earthquake engineering, Apr. 2018, v. 107, p. 20-34
Abstract: This paper presents the energy factor of trilinear single-degree-of-freedom (SDOF) systems representing low-to-medium rise damage-control buildings equipped with energy dissipation fuses under near-fault earthquake ground motions, and the focus is given to the ultimate stage of the systems. The hysteretic behaviour of a damage-control building structure with energy dissipation fuses is firstly idealised by the trilinear kinematic model, and the rationality of the trilinear idealisation is validated by the test result of a representative damage-control structure. Subsequently, the hysteretic law is assigned to SDOF systems and the seismic demand of the systems quantified by the energy factor is examined through extensive nonlinear dynamic analyses with an ensemble of near-fault earthquake ground motions as input excitations. Based on the statistical investigations of more than twenty-one (21) million inelastic spectral analyses of SDOF systems subjected to ground motions, the effect of the post-yielding stiffness ratios and the corresponding inelastic deformation range of the multiple yielding stages on the energy factor of the trilinear SDOF systems are examined in detail, and the corresponding empirical expressions for quantifying the energy factor demand are also developed. The observations of this work show that the energy factor of trilinear SDOF systems subjected to near-fault earthquake ground motions is appreciably influenced by the hysteretic parameters in multiple yielding stages, and engineers have sufficient flexibility to modulate the seismic energy balance of the system by adjusting these influential parameters. The proposed empirical expressions offer a practical tool for estimating the energy factor of a low-to-medium rise damage-control buildings equipped with energy dissipation fuses subjected to near-fault ground motions in the preliminary design phase.
Keywords: Damage-control
Energy dissipation fuse
Energy factor
Near-fault earthquake
Trilinear systems
Publisher: Elsevier Ltd
Journal: Soil dynamics and earthquake engineering 
ISSN: 0267-7261
EISSN: 1879-341X
DOI: 10.1016/j.soildyn.2017.12.023
Rights: © 2017 Elsevier Ltd. All rights reserved.
© 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Ke, K., Zhao, Q., Yam, M. C., & Ke, S. (2018). Energy factors of trilinear SDOF systems representing damage-control buildings with energy dissipation fuses subjected to near-fault earthquakes. Soil Dynamics and Earthquake Engineering, 107, 20-34 is available at https://doi.org/10.1016/j.soildyn.2017.12.023.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Zhao_Energy_Factors_Trilinear.pdfPre-Published version15.47 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

96
Last Week
5
Last month
Citations as of Nov 30, 2025

Downloads

40
Citations as of Nov 30, 2025

SCOPUSTM   
Citations

35
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

29
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.