Title: Ventilation of air-conditioned residential buildings : a case study in Hong Kong
Authors: Ai, ZT 
Mak, CM 
Cui, DJ 
Xue, P 
Issue Date: 1-Sep-2016
Source: Energy and buildings, 1 Sept. 2016, v. 127, p. 116-127
Abstract: More and more studies reported that there were insufficient ventilation and excessive CO2 concentration in air-conditioned residential buildings, but few solutions were provided. This study investigates the overnight evolution of CO2 concentration in air-conditioned residential buildings and then focuses mainly on the evaluation of three ventilation strategies, including overnight natural ventilation, short-term mechanical ventilation and short-term natural ventilation. On-site measurements were conducted in a typical residential bedroom in Hong Kong in September. The indoor and outdoor CO2 concentration, air temperature and relative humidity as well as the outdoor wind speed during the measurements were analysed. Ventilation rates were calculated based on the time series of CO2 concentration. This study confirms that additional ventilation is usually needed in air-conditioned residential buildings. Overnight natural ventilation with even a small opening is associated with excessive energy consumption and deteriorated indoor thermal environment. Short-term natural ventilation strategies are inefficient and uncontrollable. Compared to the best short-term natural ventilation strategy, a reasonably designed short-term mechanical ventilation strategy requires only a 41% of ventilation period to complete one full replacement of indoor air and to reach a lower indoor CO2 concentration. Nighttime case studies and a theoretical analysis suggest that a few several-minute mechanical ventilation periods could potentially maintain an acceptable indoor air quality for a normal sleeping period of 8 h.
Keywords: Carbon dioxide (CO2)
On-site measurements
Residential buildings
Room air conditioner
Ventilation
Publisher: Elsevier
Journal: Energy and buildings 
ISSN: 0378-7788
EISSN: 1872-6178
DOI: 10.1016/j.enbuild.2016.05.055
Rights: © 2016 Elsevier B.V. All rights reserved.
© 2016. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Ai, Z. T., Mak, C. M., Cui, D. J., & Xue, P. (2016). Ventilation of air-conditioned residential buildings: A case study in hong kong. Energy and Buildings, 127, 116-127 is available at https://doi.org/10.1016/j.enbuild.2016.05.055.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Mak_Ventilation_Air-Conditioned_Residential.pdfPre-Published version1.43 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

100
Last Week
5
Last month
Citations as of Nov 9, 2025

Downloads

116
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

55
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

47
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.