| Title: | Ventilation of air-conditioned residential buildings : a case study in Hong Kong | Authors: | Ai, ZT Mak, CM Cui, DJ Xue, P |
Issue Date: | 1-Sep-2016 | Source: | Energy and buildings, 1 Sept. 2016, v. 127, p. 116-127 | Abstract: | More and more studies reported that there were insufficient ventilation and excessive CO2 concentration in air-conditioned residential buildings, but few solutions were provided. This study investigates the overnight evolution of CO2 concentration in air-conditioned residential buildings and then focuses mainly on the evaluation of three ventilation strategies, including overnight natural ventilation, short-term mechanical ventilation and short-term natural ventilation. On-site measurements were conducted in a typical residential bedroom in Hong Kong in September. The indoor and outdoor CO2 concentration, air temperature and relative humidity as well as the outdoor wind speed during the measurements were analysed. Ventilation rates were calculated based on the time series of CO2 concentration. This study confirms that additional ventilation is usually needed in air-conditioned residential buildings. Overnight natural ventilation with even a small opening is associated with excessive energy consumption and deteriorated indoor thermal environment. Short-term natural ventilation strategies are inefficient and uncontrollable. Compared to the best short-term natural ventilation strategy, a reasonably designed short-term mechanical ventilation strategy requires only a 41% of ventilation period to complete one full replacement of indoor air and to reach a lower indoor CO2 concentration. Nighttime case studies and a theoretical analysis suggest that a few several-minute mechanical ventilation periods could potentially maintain an acceptable indoor air quality for a normal sleeping period of 8 h. | Keywords: | Carbon dioxide (CO2) On-site measurements Residential buildings Room air conditioner Ventilation |
Publisher: | Elsevier | Journal: | Energy and buildings | ISSN: | 0378-7788 | EISSN: | 1872-6178 | DOI: | 10.1016/j.enbuild.2016.05.055 | Rights: | © 2016 Elsevier B.V. All rights reserved. © 2016. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/. The following publication Ai, Z. T., Mak, C. M., Cui, D. J., & Xue, P. (2016). Ventilation of air-conditioned residential buildings: A case study in hong kong. Energy and Buildings, 127, 116-127 is available at https://doi.org/10.1016/j.enbuild.2016.05.055. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Mak_Ventilation_Air-Conditioned_Residential.pdf | Pre-Published version | 1.43 MB | Adobe PDF | View/Open |
Page views
100
Last Week
5
5
Last month
Citations as of Nov 9, 2025
Downloads
116
Citations as of Nov 9, 2025
SCOPUSTM
Citations
55
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
47
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.