Title: Quantitative evaluation of the impact of building load characteristics on energy performance of district cooling systems
Authors: Yan, C 
Gang, W 
Niu, X
Peng, X
Wang, S 
Issue Date: 1-Nov-2017
Source: Applied energy, 1 Nov. 2017, v. 205, p. 635-643
Abstract: With the rapid increase of research and application of district cooling systems (DCS), the controversy whether DCS is really energy-efficient is intensifying. Building load characteristics of DCS may be a main reason for this controversy. However, how building load characteristics affect the energy performance and which load characteristics can ensure a high performance? To answer such critical questions and improve the energy performance of DCS, this paper presents a systematic method for quantitative analysis and evaluation of the impact of building load characteristics on the energy performance of DCS. Key energy performance indicators are proposed. The load characteristics of DCS are described and quantified by introducing the concept of Lorenz curve and Gini coefficient. “Grouping coefficient” is proposed to evaluate the rationality of grouping different buildings into the same branch of chilled water distribution system. Case studies are conducted to investigate the performance of DCS under different load characteristics and to compare with conventional cooling systems. The impact of Gini coefficient and grouping coefficient on the energy performance of chiller plant, chilled water distribution system and the whole DCS are analysed. Recommendations are provided for future's application of DCS and individual cooling systems.
Keywords: Chilled water system
District cooling system
Energy efficiency
Gini coefficient
Load characteristic
Publisher: Pergamon Press
Journal: Applied energy 
ISSN: 0306-2619
EISSN: 1872-9118
DOI: 10.1016/j.apenergy.2017.08.022
Rights: © 2017 Elsevier Ltd. All rights reserved.
© 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Yan, C., Gang, W., Niu, X., Peng, X., & Wang, S. (2017). Quantitative evaluation of the impact of building load characteristics on energy performance of district cooling systems. Applied Energy, 205, 635-643 is available at https://doi.org/10.1016/j.apenergy.2017.08.022.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Wang_Quantitative_Evaluation_Impact.pdfPre-Published version1.16 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

100
Last Week
4
Last month
Citations as of Nov 9, 2025

Downloads

156
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

24
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

21
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.