Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/102915
PIRA download icon_1.1View/Download Full Text
Title: Numerical study on the impact of runner inlet arc angle on the performance of inline cross-flow turbine used in urban water mains
Authors: Du, J 
Shen, Z 
Yang, H 
Issue Date: 1-Sep-2018
Source: Energy, 1 Sept. 2018, v. 158, p. 228-237
Abstract: The inline cross-flow turbine is a promising and reliable device to harvest hydropower in an urban water supply pipeline for power supply to its water supply monitoring system. However, investigations about the influencing factors on the performance of inline cross-flow turbines are still rare and this paper focuses on the effect of their runner inlet arc angle for improving the device's performance. Firstly, a mathematical design method for the turbine's blocks is developed. With the proposed method, four models with different runner inlet arc angles are developed. The turbine's performance, function of conversion block, flow velocity characteristics, pressure distribution and blades torque output of the models are then analyzed. Results indicate that a smaller runner inlet arc can increase the flow velocity at runner inlet and pressure difference between the upstream and downstream of the runner, resulting in a higher output power but also a higher overall water head reduction through the turbine. Besides, it is found that the runner inlet arc angle has a significant influence on the power output of runner second stage. With the increase of runner inlet arc angle, the torque output at the second stage encounters a gradual decrease. To achieve a good balance between turbine efficiency and water head reduction, the suggested runner inlet arc angle is 105°. Numerical results showed that the model with 105° runner inlet arc angle could produce a maximum power generation efficiency of 42.6% with about 1.6 kW power output.
Keywords: Inline cross-flow turbine
Micro hydropower
Runner inlet arc angle
Urban water mains
Publisher: Pergamon Press
Journal: Energy 
ISSN: 0360-5442
EISSN: 1873-6785
DOI: 10.1016/j.energy.2018.06.033
Rights: © 2018 Elsevier Ltd. All rights reserved.
© 2018. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Du, J., Shen, Z., & Yang, H. (2018). Numerical study on the impact of runner inlet arc angle on the performance of inline cross-flow turbine used in urban water mains. Energy, 158, 228-237 is available at https://doi.org/10.1016/j.energy.2018.06.033.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Yang_Numerical_Study_Impact.pdfPre-Published version2.09 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

76
Last Week
3
Last month
Citations as of Nov 9, 2025

Downloads

82
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

22
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

20
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.